background image

MODELS  192 • 194 • 198

Page 8

 KEY 

PART

  NO. 

NUMBER 

PART DESCRIPTION

 

1  97009334 Housing

 

99390015 

Grounding Clip

 

99030190 

Fan Delay

 

98006989 

Element Bracket (2 Required)

 

99271155 

Heating Element (Model 192)

 

 

99270723 

Heating Element (Model 194)

 

 

99270724 

Heating Element (Model 198)

 6 

99400061  Bushing

 

97008688 

Black Wire Assembly (29–1/2”)

 

97008690 

Black Jumper Wire

 

Thermal Overload Bracket

  10 

Thermal Overload

  11 

97008692 

Red Power Wire

  12 

99150491 

Screw, 8–18 x 3/8 Ph. Pan Head  

(14 Required)

  13 

97008683 

Partition Plate Assembly

  14 

93270619 

Wire Clamp ( 3 Required)

  15 

99260425 

Nut, 8–32 Hex Keps (2 Required)

  20 

99160350 

Screw, 6–32 x 1/4 Ph. Pan Head  

(2 Required)

 21 

99030324  Thermostat

  22 

99080251 

Motor (Model 198)

  23 

99080249 

Motor (Models 192 & 194)

  24 

99020255 

Fan Blade

 25 

97013822  Grille

  26 

99150478 

Screw, 8–18 x 3/8 PH Truss Hd.  

(4 Required)

  27 

99090683 

Grille Logo

 29 

99360136  Knob

  30 

99110687 

Security Cover

  31 

93150462 

Screw, 8–18 x 5/8 Oval Head (2 Required)

 

97013945 

Assembly, Thermal Overload (Includes 

Key Nos. 9, 10, & 12 (2))

SERVICE PARTS

WARRANTY

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products 

that such products will be free from defects in materials or workmanship 

for a period of one year from the date of original purchase. THERE ARE NO 

OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIM-

ITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR 

A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or re-

place, without charge, any product or part which is found to be defective 

under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, 

TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, 

ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This 

warranty does not cover (a) normal maintenance and service or (b) any 

products or parts which have been subject to misuse, negligence, accident, 

improper maintenance or repair (other than by Broan-NuTone), faulty installa-

tion or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as 

specified for the express warranty. Some states do not allow limitation on 

how long an implied warranty lasts, so the above limitation may not apply 

to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-

NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 

REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE 

FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT 

OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some 

states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state. This warranty supersedes all prior war-

ranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the ad-

dress or telephone number below, (b) give the model number and part iden-

tification and (c) describe the nature of any defect in the product or part. At 

the time of requesting warranty service, you must present evidence of the 

original purchase date.
Broan-NuTone LLC

926 W. State Street, Hartford, Wisconsin 53027

www.broan.com    800-558-1711

Product specifications

subject to change

without notice.

99045032A

Summary of Contents for 026715022670

Page 1: ...when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 7 Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a reputable electrician before reusing 8 Do not use outdoors 9 To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel or oper...

Page 2: ...o supply the heater with proper line voltage and appropriate power cable NOTE Power can be tapped from a nearby circuit depending on the heater wattage required and the amperage rating of the circuit Heater can be converted to half wattage to avoid overloading such circuits MODEL VOLTS AMPS WATTS BTU HR 192 240 8 33 4 17 2000 1000 6827 3413 194 240 12 50 6 25 3000 1500 10240 5120 198 240 16 67 8 3...

Page 3: ... bustibles at least 3 feet 0 9 m from the front of the heater and away from the side and rear HEATER ASSEMBLY MOUNTING SCREWS THERMAL OVERLOAD RESET BUTTON THERMOSTAT MEASURING GUIDES NAIL HERE BOTH SIDES 2 Attach housing to wall studs NOTE Locate housing at least 12 from floor on any adjacent walls Use the measuring guides on the sides of housing to position housing so that it will be flush with ...

Page 4: ...mperature control GROUNDING CLIP DETAIL OPTIONAL WIRING CONVERSIONS When using a separate wall control simply turn the heater s built in thermostat to its highest set ting There is no need to disconnect the built in thermostat a Turn built in thermostat to highest setting b Remove knob c Fasten security cover to grille LINE VOLTAGE THERMOSTAT If wall mounted control is desired use the Model 86W Li...

Page 5: ...g with four 4 screws Check thermal overload button marked RESET Heater will not operate unless this button is depressed 3 Install grille Place grille over heater and attach with four 4 screws Push knob onto thermo stat stem 4 Attach security cover to grille optional When heater is installed in a public area without a separate wall control it is recommended that a Built in thermostat be set to desi...

Page 6: ...ions Purchase these accessories separately THERMAL OVERLOAD PROTECTOR Your heater is equipped with a manual reset ther mal overload protector If heater fails to operate when thermostat is turned to its highest setting 1 Turn off power at service entrance 2 Remove knob and grille 3 Press button marked RESET This type of device is particularly useful compared to automatic reset devices because it en...

Page 7: ...stomer service department at 800 558 1711 LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille openings or wipe grille clean with a soft cloth 4 Restore power CAUTION METAL AND ELECTRICAL PARTS SH...

Page 8: ...er normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUSES FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone fau...

Page 9: ...tador cerca de niños o personas inválidas y siempre que el calentador se deje funcionando y sin atención LEA Y CONSERVE ESTAS INSTRUCCIONES 7 No haga funcionar ningún calentador después de que presente una falla Desconecte la energía eléctrica en el panel de servicio y pida que un electricista acreditado inspeccione el calentador antes de volverlo a usar 8 No lo use en exteriores 9 Para desconecta...

Page 10: ...gar en que el borde del calentador se encuentre por lo menos a 30 48 cm de cualquier superficie vertical adyacente Este calentador se puede poner en funcionamiento usando su termostato incorporado o un termostato a distancia por ejemplo el termostato de tensión de línea Modelo 86 o un termostato de bajo voltaje ap ropiado y transformador relé El conjunto Modelo 85 está disponible para aplicaciones...

Page 11: ...R BOTON RESET DE SOBRE CARGA TERMICA TERMOSTATO GUIDAS DE MEDIDA CLAVE AQUI EN AMBOS LADOS 1 Saque el conjunto de calentador de la caja Saque los cuatro 4 tornillos que se muestran y saque el conjunto del calentador 2 Enganche la caja en las vigas de la pared NOTA Sitúe la caja a una distancia por lo menos de 30 48 cm del piso o de cualquier pared adya cente Use las guías de medida al costado de l...

Page 12: ...ed con cada cable desnudo Si se desea control montado en la pared uso un termostato de bajo voltaje apropiado compre por separado Siga las instrucciones de montaje y cableado que vienen con los controles CABLEADO El trabajo de instalación y el cableado eléctrico deben estar a cargo de personal capacitado de acuerdo con todos los códigos y normas correspondientes incluidos los códigos y normas de c...

Page 13: ...obrecarga térmica El calentador no funcionará a menos que el botón esté oprimido 3 Instale la rejilla Coloque la rejilla sobre el calen tador y fíjelo con cuatro 4 tornillos Empuje la perilla en el vástago del termostato 4 Fije la cubierta de seguridad a la rejilla opcio nal Cuando se instala el calentador en un área pública sin un control de pared separado se recomienda a Graduar el termostato in...

Page 14: ... accesorios por separado PROTECTOR DE SOBRECARGA TERMICA Su calentador cuenta con un protector de sobrecarga térmica de reposición manual Si el calentador no funciona cuando el termostato está activado en su graduación más alta 1 Corte la energía en la entrada de servicio 2 Saque la perilla y la rejilla 3 Oprima el botón RESET Este tipo de dispositivo es especialmente útil com parado con los de re...

Page 15: ...ÓN El calentador está permanentemente lubricado y nunca necesitará ponerle aceite ni desarmarlo LIMPIEZA Limpie el calentador una vez al mes tal como sigue 1 Apague la energía eléctrica en el panel de ser vicio 2 Asegúrese de que el elemento de calefacción esté frío 3 Use un aditamento de cepillo suave para aspirar suavemente aberturas de la rejilla o limpie la rejilla con un paño suave 4 Restaure...

Page 16: ...so LA PRESENTE GARANTÍA NO CUBRE LOS TUBOS FLUORESCENTES NI SUS ARRANCADORES BOMBILLAS DE HALÓGENO E INCANDESCENTES FUS IBLES FILTROS CONDUCTOS TAPONES DE TECHO O PAREDES Y DEMÁS ACCESORIOS PARA CONDUCTOS Esta garantía no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma errónea negligente que hayan causado un accidente o que hayan sido re...