3. Connect the other end to the FC device.
You are ready to apply power to the computer.
2.4 Applying Power
To apply power, follow these steps:
1. Verify that the HBA is securely installed in the computer.
2. Verify that the correct media is attached.
3. Plug in the computer, and turn it on.
4. Watch the LEDs for POST results.
2.4.1 Viewing the LEDs
You can view the yellow and green LEDs through openings in the HBA's mounting bracket. The yellow LED indicates port
activity or link speed, and the green LED indicates firmware operation. Each port has a corresponding set of yellow and
green LEDs.
Figure 7: Optical HBA LED Indicators
2.4.2 POST Conditions and Results
POST is the default mode of self-test for Emulex HBAs. No jumpers or connectors are necessary for this test to run. This
test performs a quick confidence level check of the HBA when it is powered on, and before it runs the operational software.
At a minimum, the following tests are performed by POST:
Flash boot image checksum test
Internal ASIC RAM tests for proper ECC parity operation
Loopback test