Setting the domain ID
Perform the following steps to set the switch domain ID.
1. Log in to the switch through Telnet using the admin account.
2. Modify the domain ID if required.
The default domain ID is 1. If the switch is not powered on until after it is connected to the fabric and the default domain ID is
already in use, the domain ID for the new switch is automatically reset to a unique value. If the switch is connected to the fabric
after it has been powered on and the default domain ID is already in use, the fabric segments. To find the domain IDs that are
currently in use, enter the
fabricShow
command on another switch in the fabric.
Perform the following steps to modify the domain ID.
a)
Disable the switch by entering the
switchDisable
command.
b) Enter the
configure
command. The command prompts display sequentially; enter a new value or press
Enter
to accept
each default value.
c)
Enter
y
after the "Fabric param" prompt.
Fabric param (yes, y, no, n): [no] y
d) Enter a unique domain ID (such as the domain ID used by the previous switch, if still available).
Domain: (1..239) [1] 3
e)
Complete the remaining prompts or press
Ctrl+D
to accept the remaining settings without completing all the prompts.
f)
Re-enable the switch by entering the
switchEnable
command.
Verifying correct operation
Perform the following steps to verify correct operation of the device.
1. Check the LEDs to verify that all components are functional.
Setting the domain ID
Brocade G630 Hardware Installation Guide
54
53-1005235-02
Summary of Contents for Brocade G630
Page 10: ...Brocade G630 Hardware Installation Guide 10 53 1005235 02 ...
Page 22: ...Brocade G630 Hardware Installation Guide 22 53 1005235 02 ...
Page 48: ...Brocade G630 Hardware Installation Guide 48 53 1005235 02 ...
Page 72: ...Brocade G630 Hardware Installation Guide 72 53 1005235 02 ...
Page 88: ...Brocade G630 Hardware Installation Guide 88 53 1005235 02 ...
Page 96: ...Brocade G630 Hardware Installation Guide 96 53 1005235 02 ...
Page 100: ...Brocade G630 Hardware Installation Guide 100 53 1005235 02 ...