VAD-2 Plus Installation and Operation Manual

PROGRAMMING

Applications

Silence Monitor III. DMS III and/or LOV II alarm notification, Tower Light

malfunction and/or operation, Transmitter, Translator and/or LPFM site and Studio
security/burglar/fire/equipment alarm notification, Inexpensive remote control sys-
tem and/or remote reset (ac power reboot) of file servers, computers, etc.  
Back-up program switching with optional customized firmware and hardware.  

Inspection

Please examine your VAD-2 Plus carefully for any damage that may have

been sustained during shipping.  If any is noted, please notify the shipper immedi-
ately and retain the packaging for inspection by the shipper.  The package should
contain the VAD-2 Plus, this manual, 7 foot modular telephone cable and the 12
VAC @ 500 ma or 1 amp wall transformer.

Programming

The VAD-2 Plus can be programmed either locally using the front panel

recessed PGM button or remotely using the program access code.  To program local-
ly, please following the steps below:

1 - Locate the front panel modular RJ-11 jack labeled “Phone Pgm” and plug in a

standard TT telephone  

2 - Press the recessed front panel “PGM” button; the front panel “PGM” led will

illuminate.

3 – Enter the command code of the desired operation, followed by the data to be

stored or the message to be recorded.  Note:  Refer to pages 6 through 9

4 After entering the data or recording voice messages, press the recessed front panel

“PGM” button to exit programming mode.  The “PGM” led should extinguish.

When programming remotely, you must call the VAD-2 Plus and enter the

access code.  If you call and enter the un-lock security code, you cannot then enter
the access code and perform programming functions.  Terminate each item pro-
grammed with the “#” (pound) key.  The access code can only be entered when the
VAD-2 Plus is in a locked condition, and only programming can be done.  You must
hang up to exit program mode.  Multiple parameters and voice messages can be pro-
grammed remotely in one session.

The following is a list of data items that can be programmed along with the

2 digit programming code and the maximum number of digits that can be entered,
along with the factory default data.  To program any of these items, press the pro-
gram button, enter the two-digit address, followed by the data.  If you enter more
than the maximum allowed, the excess characters will be ignored.

Programming

Summary of Contents for tiny TOOLS VAD - 2 Plus

Page 1: ...d trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tool...

Page 2: ...ing you equipment 10 Status inputs 10 Silence sensor inputs 10 Power failure input 11 Temperature probe 11 External power supply output 11 Relays 11 Telco Caller audio output 11 Power supply input 11...

Page 3: ...re problems If you experience these problems please research your hardware software instruction man uals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have a...

Page 4: ...arm is activated Features Two user programmable wet or dry optically isolated status inputs Optional Fahrenheit Celsius temperature sensor probe Stereo Silence Sensor with remote telco audio monitorin...

Page 5: ...ack labeled Phone Pgm and plug in a standard TT telephone 2 Press the recessed front panel PGM button the front panel PGM led will illuminate 3 Enter the command code of the desired operation followed...

Page 6: ...ode You must call the VAD 2 Plus and enter the remote access code Dial List is a list of the Dial out phone numbers that will be dialed for a particular alarm The numbers correspond to the dial out ad...

Page 7: ...ensor Delay Timer 31 1 3 The delay time is programmed with a value of 1 to 9 with values as follows 1 10 secs 2 30 secs 3 60 secs 4 90 secs 5 2 mins 6 2 5 mins 7 3 mins 8 4 mins and 9 5 mins Power Fai...

Page 8: ...the new message using the programming phone When done press the PGM button again or wait for the time out When recording remotely you must first dial in and enter the remote access code The VAD 2 Plu...

Page 9: ...Silent Sensor is disabled then when input 1 closes the VAD 2 Plus will dial out the number assigned to the Dial List 1 location If the input remains closed for 15 seconds relay 1 will close and caller...

Page 10: ...er The IN 1 jumpers support status input one while IN 2 supports status input two Each input is labeled IN x where x is the status input and the header pins are labeled from left to right 1 2 3 4 as v...

Page 11: ...for relay one is between the K1NO K1NC and K1CM terminals Relay two is between terminals K2NO K2NC and K2CM Limit contact current to 1 amp at 30 vdc Note For safety never connect 120 Vac circuits to...

Page 12: ...the VAD 2 Plus is ready to receive commands after the secu rity un lock code is entered through your telephone keypad Functions include telling the VAD 2 Plus to report on the input state of any of t...

Page 13: ...elay 1 1 second pulse 1 Relay 1 latched 1 Relay 1 un latched 21 Enable Input 2 alarm 22 Disable Input 2 alarm 23 Poll Input 2 Enable Status 27 Poll Input 2 State Status 28 Poll Relay 2 29 Steady Relay...

Page 14: ...d in an alarm condition Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid DTMF tone Pwr led OFF in voice record mode Hook led ON when in an of...

Page 15: ...0K ohm inputs Trip level 20dBu Silence sensor level to Telco adjustable Balanced caller audio output 0 dbu 100 ohms Gain may be changed to increase output Telephone Line Connector RJ 11 Cable supplied...

Page 16: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Page 17: ...OFF with NO audio SS led flashes if enabled and in an alarm condition Optional Temp Probe Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid D...

Page 18: ...5678 then press the front panel recessed program push button to exit programming mode 7 Press the front panel recessed program push button to enter programming mode 8 Enter the memory location you nee...

Page 19: ...essed program push button to exit programming mode 23 Press the front panel recessed program push button to enter programming mode 24 Enter the memory location you need to program Example Number of LA...

Page 20: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 20 APPENDIX...

Page 21: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 21 APPENDIX...

Reviews: