Broadcast Tools tiny TOOLS VAD - 2 Plus Installation And Operation Manual Download Page 17

131 State Street, Sedro-Woolley, WA 98284 • 360.854.9559 • Fax 866.783.9479

Visit us online at www.broadcasttools.com

Copyright © 1989-2008 by Broadcast Tools, Inc. All Rights Reserved.

VAD-2 Plus  

Voice Alarm Dialer

  Two Input Voice Dialer with Silence Sensor and Dual Relay Control

Phone

PGM

Power

Hook

K1

K2

PGM

SS

Temp.

PWR/12VAC

Telco

SS-Mon

K1

NC

K1

CM

K1

NO

ST

1A

ST

1B

+5

VD

C

Gn

d

Ch

s G

nd

PF

+

PF

SS led ON with valid audio
SS led OFF with NO audio
SS led flashes if enabled and in an alarm condition

Optional

Temp Probe

Pwr led ON if powered
Pwr led flashes if PF is enabled and in an alarm condition
Pwr led OFF during a valid DTMF tone
Pwr led OFF in voice record mode.

Hook led ON
when in an off-
hook condition

K1 led ON when
K1 is closed or
energized
 

K2 led ON when
K2 is closed or
energized

PGM led ON when
programming the
VAD-2 Plus

Recessed Program Switch

Voice/Program TT
Telephone Receptacle

Telephone
Line

Silence Sensor (send)
audio to telco level trimmer

12 VAC wall
transformer
receptacle

K2

NC

K2

CM

K2

NO

ST

2A

ST

2B

SS

L

SS

R

GN

D

CL

R–

CL

R+

Summary of Contents for tiny TOOLS VAD - 2 Plus

Page 1: ...d trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tool...

Page 2: ...ing you equipment 10 Status inputs 10 Silence sensor inputs 10 Power failure input 11 Temperature probe 11 External power supply output 11 Relays 11 Telco Caller audio output 11 Power supply input 11...

Page 3: ...re problems If you experience these problems please research your hardware software instruction man uals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have a...

Page 4: ...arm is activated Features Two user programmable wet or dry optically isolated status inputs Optional Fahrenheit Celsius temperature sensor probe Stereo Silence Sensor with remote telco audio monitorin...

Page 5: ...ack labeled Phone Pgm and plug in a standard TT telephone 2 Press the recessed front panel PGM button the front panel PGM led will illuminate 3 Enter the command code of the desired operation followed...

Page 6: ...ode You must call the VAD 2 Plus and enter the remote access code Dial List is a list of the Dial out phone numbers that will be dialed for a particular alarm The numbers correspond to the dial out ad...

Page 7: ...ensor Delay Timer 31 1 3 The delay time is programmed with a value of 1 to 9 with values as follows 1 10 secs 2 30 secs 3 60 secs 4 90 secs 5 2 mins 6 2 5 mins 7 3 mins 8 4 mins and 9 5 mins Power Fai...

Page 8: ...the new message using the programming phone When done press the PGM button again or wait for the time out When recording remotely you must first dial in and enter the remote access code The VAD 2 Plu...

Page 9: ...Silent Sensor is disabled then when input 1 closes the VAD 2 Plus will dial out the number assigned to the Dial List 1 location If the input remains closed for 15 seconds relay 1 will close and caller...

Page 10: ...er The IN 1 jumpers support status input one while IN 2 supports status input two Each input is labeled IN x where x is the status input and the header pins are labeled from left to right 1 2 3 4 as v...

Page 11: ...for relay one is between the K1NO K1NC and K1CM terminals Relay two is between terminals K2NO K2NC and K2CM Limit contact current to 1 amp at 30 vdc Note For safety never connect 120 Vac circuits to...

Page 12: ...the VAD 2 Plus is ready to receive commands after the secu rity un lock code is entered through your telephone keypad Functions include telling the VAD 2 Plus to report on the input state of any of t...

Page 13: ...elay 1 1 second pulse 1 Relay 1 latched 1 Relay 1 un latched 21 Enable Input 2 alarm 22 Disable Input 2 alarm 23 Poll Input 2 Enable Status 27 Poll Input 2 State Status 28 Poll Relay 2 29 Steady Relay...

Page 14: ...d in an alarm condition Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid DTMF tone Pwr led OFF in voice record mode Hook led ON when in an of...

Page 15: ...0K ohm inputs Trip level 20dBu Silence sensor level to Telco adjustable Balanced caller audio output 0 dbu 100 ohms Gain may be changed to increase output Telephone Line Connector RJ 11 Cable supplied...

Page 16: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Page 17: ...OFF with NO audio SS led flashes if enabled and in an alarm condition Optional Temp Probe Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid D...

Page 18: ...5678 then press the front panel recessed program push button to exit programming mode 7 Press the front panel recessed program push button to enter programming mode 8 Enter the memory location you nee...

Page 19: ...essed program push button to exit programming mode 23 Press the front panel recessed program push button to enter programming mode 24 Enter the memory location you need to program Example Number of LA...

Page 20: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 20 APPENDIX...

Page 21: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 21 APPENDIX...

Reviews: