LIMITED WARRANTY

LIMITED WARRANTY

The term “Buyer” as used in this document refers to and includes both (but only) (a) any person or entity who acquires such an item for
the purpose of resale to others (i.e., a dealer or distributor of an item), and (b) the first person or entity who acquires such an item for
such person’s or entity’s own use. 

Broadcast Tools warrants to each Buyer of any item manufactured by Broadcast Tools that the item will be free from defects in materi-
als and workmanship at the time it is shipped by Broadcast Tools if the item is properly installed, used and maintained. 

EXCLUSIVE REMEDIES

If Broadcast Tools is notified, in writing, of a failure of any item manufactured by Broadcast Tools to conform to the foregoing Limited
Warranty within one (1) year following the date of the Buyer’s acquisition of the item, and if the item is returned to Broadcast Tools in
accordance with Broadcast Tools’ instructions for confirmation by inspection of the defect (which at Broadcast Tools’ election may
include, without limitation, a requirement that the Buyer first obtain a Return Authorization number from Broadcast Tools, that the Buyer
furnish proof of purchase in the form of an invoice and/or receipt, and that the Buyer prepay all freight charges associated with any return
of the item to Broadcast Tools using such freight service as Broadcast Tools reasonably may specify), Broadcast Tools will repair or
replace the defective item, or will refund the purchase price paid by the Buyer for the item.  Broadcast Tools shall have the exclusive
right to choose between these alternative remedies.

NO OTHER WARRANTIES OR REMEDIES

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, BROADCAST TOOLS AND ITS SUPPLIERS DISCLAIM ALL OTHER
WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE; AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF
ALL OTHER REMEDIES.  THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS.  YOU MAY HAVE OTHER RIGHTS,
WHICH VARY FROM STATE/JURISDICTION TO STATE/JURISDICTION.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, NEITHER BROADCAST TOOLS NOR ANY OF ITS SUPPLIERS
SHALL HAVE ANY LIABILITY FOR ANY SPECIAL, INCIDENTAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES WHATSO-
EVER (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES FOR LOST PROFITS, BUSINESS INTERRUPTION, LOSS OF DATA OR
INFORMATION, COST OF CAPITAL, CLAIMS OF CUSTOMERS, OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE
OF OR THE INABILITY TO USE ANY ITEM SUPPLIED BY BROADCAST TOOLS, EVEN IF BROADCAST TOOLS HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES HAVE ANY LIABILITY FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL,
EXEMPLARY OR PUNITIVE DAMAGES.  THIS LIMITATION OF LIABILITY APPLIES WHETHER A CLAIM IS ONE ALLEGING
BREACH OF A CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT, FOR THE VIOLATION OF ANY STATUTORY DUTY,
THE FAILURE OF ANY LIMITED OR EXCLUSIVE REMEDY TO ACHIEVE ITS ESSENTIAL PURPOSE, OR ANY OTHER CLAIM OF
ANY NATURE.  BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, THIS LIMITATION MAY NOT APPLY TO YOU.

Broadcast Tools,  Inc.

131 State Street

Sedro-Woolley, WA 98284 • USA

360.854.9559 

voice 

866.783.1742 

fax

[email protected] 

e-mail

www.broadcasttools.com 

website

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742 

Summary of Contents for tiny TOOLS VAD - 2 Plus

Page 1: ...d trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tool...

Page 2: ...ing you equipment 10 Status inputs 10 Silence sensor inputs 10 Power failure input 11 Temperature probe 11 External power supply output 11 Relays 11 Telco Caller audio output 11 Power supply input 11...

Page 3: ...re problems If you experience these problems please research your hardware software instruction man uals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have a...

Page 4: ...arm is activated Features Two user programmable wet or dry optically isolated status inputs Optional Fahrenheit Celsius temperature sensor probe Stereo Silence Sensor with remote telco audio monitorin...

Page 5: ...ack labeled Phone Pgm and plug in a standard TT telephone 2 Press the recessed front panel PGM button the front panel PGM led will illuminate 3 Enter the command code of the desired operation followed...

Page 6: ...ode You must call the VAD 2 Plus and enter the remote access code Dial List is a list of the Dial out phone numbers that will be dialed for a particular alarm The numbers correspond to the dial out ad...

Page 7: ...ensor Delay Timer 31 1 3 The delay time is programmed with a value of 1 to 9 with values as follows 1 10 secs 2 30 secs 3 60 secs 4 90 secs 5 2 mins 6 2 5 mins 7 3 mins 8 4 mins and 9 5 mins Power Fai...

Page 8: ...the new message using the programming phone When done press the PGM button again or wait for the time out When recording remotely you must first dial in and enter the remote access code The VAD 2 Plu...

Page 9: ...Silent Sensor is disabled then when input 1 closes the VAD 2 Plus will dial out the number assigned to the Dial List 1 location If the input remains closed for 15 seconds relay 1 will close and caller...

Page 10: ...er The IN 1 jumpers support status input one while IN 2 supports status input two Each input is labeled IN x where x is the status input and the header pins are labeled from left to right 1 2 3 4 as v...

Page 11: ...for relay one is between the K1NO K1NC and K1CM terminals Relay two is between terminals K2NO K2NC and K2CM Limit contact current to 1 amp at 30 vdc Note For safety never connect 120 Vac circuits to...

Page 12: ...the VAD 2 Plus is ready to receive commands after the secu rity un lock code is entered through your telephone keypad Functions include telling the VAD 2 Plus to report on the input state of any of t...

Page 13: ...elay 1 1 second pulse 1 Relay 1 latched 1 Relay 1 un latched 21 Enable Input 2 alarm 22 Disable Input 2 alarm 23 Poll Input 2 Enable Status 27 Poll Input 2 State Status 28 Poll Relay 2 29 Steady Relay...

Page 14: ...d in an alarm condition Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid DTMF tone Pwr led OFF in voice record mode Hook led ON when in an of...

Page 15: ...0K ohm inputs Trip level 20dBu Silence sensor level to Telco adjustable Balanced caller audio output 0 dbu 100 ohms Gain may be changed to increase output Telephone Line Connector RJ 11 Cable supplied...

Page 16: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Page 17: ...OFF with NO audio SS led flashes if enabled and in an alarm condition Optional Temp Probe Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid D...

Page 18: ...5678 then press the front panel recessed program push button to exit programming mode 7 Press the front panel recessed program push button to enter programming mode 8 Enter the memory location you nee...

Page 19: ...essed program push button to exit programming mode 23 Press the front panel recessed program push button to enter programming mode 24 Enter the memory location you need to program Example Number of LA...

Page 20: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 20 APPENDIX...

Page 21: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 21 APPENDIX...

Reviews: