VAD-2 Plus Installation and Operation Manual
OPERATION
Control Codes
All Control codes are two digits long and will be active after the VAD-2 Plus
has received its security (un-lock) code.
Code
Function
03
Caller out Audio ON
04
Caller out Audio OFF
07
Silence Sensor Audio to telco ON
08
Silence Sensor Audio to telco OFF
11
Enable Input 1 alarm
12
Disable Input 1 alarm
13
Poll Input 1 Enable status
17
Poll Input 1 State status
18
Poll Relay 1
19
Steady Relay output (for duration of DTMF tone)
10
Relay 1 – 1-second pulse
1*
Relay 1 latched
1#
Relay 1 un-latched
21
Enable Input 2 alarm
22
Disable Input 2 alarm
23
Poll Input 2 Enable Status
27
Poll Input 2 State Status
28
Poll Relay 2
29
Steady Relay output (for duration of DTMF tone)
20
Relay 2 – 1-second pulse
2*
Relay 2 latched
2#
Relay 2 un-latched
31
Enable Silence Sensor Alarm
32
Disable Silence Sensor Alarm
33
Poll Enable State of Silence Sensor Alarm
37
Poll Silence Sensor Alarm Input
41
Enable Power Fail Alarm
42
Disable Power Fail Alarm
43
Poll Enable State of Power Fail Alarm
47
Poll Power Fail Alarm
51
Enable Temperature Alarm
52
Disable Temperature Alarm
53
Poll Enable State of Temperature Alarm
57
Poll Current Temperature
90
Speak Firmware Version number
99
Force Manual Hang up