e-mail:
voice:
360.854.9559
fax:
866.783.1742
9
DTD-16 + G2 Installation and Operation Manual
PROGRAMMING
Programming Steps
1. Press the recessed front panel PGM button or type “p” in the terminal to enter
Program Mode. The red front panel PGM LED will blink to indicate the DTD is in
Program mode and the Program Menu will be displayed in the terminal window:
DTD-16+ VER 2.02
OUT-CMD ON/OFF CODES
01-0-0.00-1111/
02-0-0.00-2222/
03-0-0.00-3333/
04-0-0.00-4444/
05-0-0.00-5555/
06-0-0.00-6666/
07-0-0.00-7777/
08-0-0.00-8888/
09-0-0.00-9999/
10-1-0.10-101/
11-0-0.00-****/
12-0-0.00-####/
13-0-0.00-AAAA/
14-0-0.00-BBBB/
15-0-0.00-CCCC/
16-0-0.00-DDDD/
SELECT 01-16 & ENTER 0=MOM, 1=LATCH, 2=XLATCH
DELAY 000-999 (0.00-9.99 SEC), MOM OR ON CODE
/ OFF CODE :
2. Type the output channel number, 01 through 16, a “- “(dash) will be displayed
after the number are entered along with a new line.
3. Type the single command digit to set the output mode: “0” for momentary, “1”
for Latch or “2” for Exclusive Latch. A “- “(dash) will be displayed after the
command digit and a new line will be displayed.
4. Enter a time delay value of 0.00 to 9.99 seconds as a three-digit value (000-999).
Do not enter the ".", it will be entered automatically. This is the time that will
elapse after a command is received and before the output is activated. Default
time delay before activation is 0.00 seconds. A “- “(dash) will be displayed after
the command digit and a new line will be displayed.
5. Enter the DTMF tone or string value(s) you want to use to operate the selected
output. The default values are listed in above.
To exit Program mode, press the ESC key. Program mode will be exited automat-
ically after 60 seconds of inactivity. When Program mode is exited the DTD will
list the current program values and perform a reset.
WEBSITE:
Visit our web site for
product updates and
additional information.