9

DC-8 Plus Installation and Operation Manual

OPERATION

BUSY INPUT

The busy input allows a user to remotely disable the DC-8 Plus from answering a
call.  By asserting this input low, no calls will be answered. 

PAGER ALERT

The DC-8 Plus includes the ability to call up to THREE outside telephone (pager)
numbers in the event any or all status inputs go "LOW" for 2 seconds or longer.  As
shown in the DC-8 Plus Command Grid, the Pager Alert function can be activated
or deactivated by entering 951 * (star), (turns on function), or 950 * (star) (turns off
function).  The user may configure any or all of the eight status inputs to trigger a
pager alert, by inserting the desired status input numbers in program 954, i.e. 9541*
(star).  (Status input one being asserted low will cause an alert.)  In order to program
the first call out telephone number, enter 961, followed by the FIRST telephone
number to a digital pager or other service.  Enter 962, followed by the SECOND
telephone number to a digital pager or other service.  Enter 963, followed by the
THIRD telephone number to a digital pager or other service.  Not all of the pager
need be entered.  In the event you would like the call back number to be displayed
on a digital pager, enter 97, followed by the return (call back) number that will dis-
play on the pager.  The DC-8 Plus will place as the FIRST digit, the FIRST STATUS
/ PAGER ALERT input that caused the ALERT.  To provide added reliability, the
DC-8 Plus dials the pager number twice.  If your Telephone Company provides
CALLER ID (ANI), this may be a simple way to replace the pager, when using the
pager alert.  

NOTE:

Any programming (EXCEPT THE ACCESS CODES and DEFAULT

SETTINGS!!) can be performed either in LOCAL mode, (OPERATE/LOCAL
button depressed), or when connected via telephone.  Please remember to
DISENGAGE the front panel OPERATE/LOCAL switch, when you are finished
programming the DC-8 Plus.

NOTE:

If the DC-8 Plus is left in LOCAL mode, the DC-8 Plus will not answer

incoming calls.

To hang up and return to the stand-by mode, either hang up or enter 99, followed by
the * (star) key.  

DC-8 Plus COMMAND GRID

This manual has provided many programming and operational functions of the
Broadcast Tools DC-8 Plus Dial-Up Remote Control.  By using the DC-8 Plus
Command Grid, additional programming and operation functions are available to
customize the DC-8 Plus to fit many needs.  We hope that like many other users
of Broadcast Tools products, you too will encounter many years of reliable and
versatile use. 

Summary of Contents for DC-8 Plus

Page 1: ...Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tools Inc All...

Page 2: ...anual Table of Contents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 FCC Notice 4 General Description 5 Additional Features 5 Typical Applications 5 Installing the...

Page 3: ...t or you need assistance please con tact your distributor from whom you purchased this equipment If you would like more information about Broadcast Tools products you may reach us at Broadcast Tools I...

Page 4: ...ion of your equipment provided you are given adequate advance written notice to permit correct operation 5 In case of operational problems disconnect your unit by removing the modular plug from the te...

Page 5: ...e acknowledgment defeat May be configured for stand alone DTMF tone decoding On power loss and restoration all relays retain their prior state Each relay may be configured to close for as long as the...

Page 6: ...alent is also suggested for the power transformer while the Tripp Lite DTEL 2 is very effective for the tele phone line The purchase of an inexpensive uninterruptible power sup ply UPS will provide ba...

Page 7: ...rol has a range of 4 dbu to OFF The balanced Auxiliary input is labeled AUX and AUX and feeds the DTMF decoder directly and may be adjusted by the AUX control on the rear panel The telephone hybrid nu...

Page 8: ...elay contact enter the star key relay number and the star key Performing this function will return the appropriate relay to an off or unlatched mode If you have selected the interlock mode only one re...

Page 9: ...r need be entered In the event you would like the call back number to be displayed on a digital pager enter 97 followed by the return call back number that will dis play on the pager The DC 8 Plus wil...

Page 10: ...ing NO access code Audio ON Auto coupler mode 900 Mode 901 off Default 911 Turns relay INTERLOCK mode ON ONE latched relay ON at a time 910 Turns relay INTERLOCK mode OFF Default 92xx Number of rings...

Page 11: ...umber ONE to dial Up to 20 digits 1 second pause Default NO number Example 96112069384433 962x x Telephone number TWO to dial Up to 20 digits 1 second pause Default NO number Example 96212069384433 96...

Page 12: ...beep is sent K1 closes for 1 2 second No tone is recorded STOP When key 2 is released K2 closes for 1 2 second and then the double acknowledgment beep is sent Note A good number of systems stop the re...

Page 13: ...ugh 8 follow the listed steps below Jumper Status inputs one and two to the DGND terminals Connect the audio output of the device to be monitored to the AUX input terminals Connection to the phone lin...

Page 14: ...sceiver Relays OC Sealed relays 6 SPDT 2 2PDT Bifurcated Crossbar silver alloy with gold overlay contacts 30 vdc 750 ma Open collector Ground Sink 24 vdc 100 ma NOTE For safety do NOT connect 120VAC c...

Page 15: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLI...

Page 16: ...e mail support broadcasttools com voice 360 854 9559 fax 360 854 9479 DC 8 Plus Installation and Operation Manual 16 APPENDIX...

Reviews: