8

DC-8 Plus Installation and Operation Manual

OPERATION

NOTE: 

THE  “MASTER” (MONITORING and CONTROL) ACCESS CODE is

entered as follows:   (STAR)* (STAR) * xxxxxxxx    The factory default is **

NOTE: 

When the DC-8 Plus receives a call, the red “RING” LED will light and

the rear panel RING open collector will go low each time the ring signal is
detected.

NOTE: 

The call will be answered after the user-programmed number of

rings.  At this time, the “HOOK” LED will light and the rear panel HOOK open
collector will go low.

NOTE:

The DC-8 Plus will hang-up if the following conditions occur: 

1 - If more than 1 minute has elapsed before a correct access code is entered.
2 - If no commands are detected for 1 minute.  CPC defeated. 
3 - If the calling party hangs up.  
4 - If command 99* (star) is entered.

CONTROLLING, OR POLLING THE RELAYS 

Relays may be selected by entering the appropriate relay number.  This command
will produce a relay action for as long as the key is held.  If you prefer a latching
contact closure, enter the # (pound) key, the relay number, followed by the * (star)
key.  Performing this function will latch the relay into the "on" mode.  To unlatch a
relay contact, enter the * (star) key, relay number, and the * (star) key.  Performing
this function will return the appropriate relay to an "off" or unlatched mode.  If you
have selected the interlock mode,  only one relay may be latched at any one time.
After each command, a double bleep will be heard acknowledging completion of the
command.  If an error tone (three warbles) is received, re-enter the command.  In
order to check the status of any relay, simply press the # (pound) key, followed by
the TWO DIGIT relay number, and the * (star) key.  A high tone will be heard if the
relay is closed and a low tone if the relay is open.  Follow the format provided with
the DC-8 Plus COMMAND GRID.

NOTE:

During a power outage, when power is returned, latched relays will

return to their pre-power outage position.

POLLING THE STATUS INPUTS 

In order to check the status of any STATUS / PAGER ALERT input, simply press
the * (star) key, followed by the TWO DIGIT status number, and then the * (star)
key.  In the event the status input condition is in a (> + 2.5 vdc) "high" condition, a
high tone will be heard.  In a “low” (ground) status condition, a low tone will be
heard. After each command, a double bleep will acknowledge completion of the
command.  If an error tone (three warbles) is received, re-enter the command.
Follow the format provided with the DC-8 Plus COMMAND GRID.

WEBSITE:

Visit our web site for
product updates and
additional information

Summary of Contents for DC-8 Plus

Page 1: ...Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tools Inc All...

Page 2: ...anual Table of Contents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 FCC Notice 4 General Description 5 Additional Features 5 Typical Applications 5 Installing the...

Page 3: ...t or you need assistance please con tact your distributor from whom you purchased this equipment If you would like more information about Broadcast Tools products you may reach us at Broadcast Tools I...

Page 4: ...ion of your equipment provided you are given adequate advance written notice to permit correct operation 5 In case of operational problems disconnect your unit by removing the modular plug from the te...

Page 5: ...e acknowledgment defeat May be configured for stand alone DTMF tone decoding On power loss and restoration all relays retain their prior state Each relay may be configured to close for as long as the...

Page 6: ...alent is also suggested for the power transformer while the Tripp Lite DTEL 2 is very effective for the tele phone line The purchase of an inexpensive uninterruptible power sup ply UPS will provide ba...

Page 7: ...rol has a range of 4 dbu to OFF The balanced Auxiliary input is labeled AUX and AUX and feeds the DTMF decoder directly and may be adjusted by the AUX control on the rear panel The telephone hybrid nu...

Page 8: ...elay contact enter the star key relay number and the star key Performing this function will return the appropriate relay to an off or unlatched mode If you have selected the interlock mode only one re...

Page 9: ...r need be entered In the event you would like the call back number to be displayed on a digital pager enter 97 followed by the return call back number that will dis play on the pager The DC 8 Plus wil...

Page 10: ...ing NO access code Audio ON Auto coupler mode 900 Mode 901 off Default 911 Turns relay INTERLOCK mode ON ONE latched relay ON at a time 910 Turns relay INTERLOCK mode OFF Default 92xx Number of rings...

Page 11: ...umber ONE to dial Up to 20 digits 1 second pause Default NO number Example 96112069384433 962x x Telephone number TWO to dial Up to 20 digits 1 second pause Default NO number Example 96212069384433 96...

Page 12: ...beep is sent K1 closes for 1 2 second No tone is recorded STOP When key 2 is released K2 closes for 1 2 second and then the double acknowledgment beep is sent Note A good number of systems stop the re...

Page 13: ...ugh 8 follow the listed steps below Jumper Status inputs one and two to the DGND terminals Connect the audio output of the device to be monitored to the AUX input terminals Connection to the phone lin...

Page 14: ...sceiver Relays OC Sealed relays 6 SPDT 2 2PDT Bifurcated Crossbar silver alloy with gold overlay contacts 30 vdc 750 ma Open collector Ground Sink 24 vdc 100 ma NOTE For safety do NOT connect 120VAC c...

Page 15: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLI...

Page 16: ...e mail support broadcasttools com voice 360 854 9559 fax 360 854 9479 DC 8 Plus Installation and Operation Manual 16 APPENDIX...

Reviews: