DC-8 Plus Installation and Operation Manual

FCC NOTICE

FCC  NOTICE TO THE  USERS

1. UPON REQUEST ONLY, you must provide the following data to your 
telephone utility company:

2. 
a)  Notice of intention to install or permanently remove an FCC Part 68 
registered device/syste, and the FCC Registration Number.  * SEE page 
14 of this manual.
b)  The Ringer Equivalence Number * SEE page 14 of this manual.  Note 
that if several devices are connected to the same line, the REN’s must not 
add up to more than 4.0 (A or B).  This REN figure is important to your 
telephone utility company.
c)  The *(USOC) jack type to be provided by the telephone utility company. 
Typically this will be RJ-11C/W for single lines.

3.  This device may not be used on telco-operated coin phone lines or party lines and
privately owned coin-phones, which are subject to local State regulatory policies,
and possible additional State special requirements.

4.  The telephone utility company has the right to make changes to their network
which may affect the operation of your equipment, provided you are given adequate
advance written notice to permit correct operation.

5.  In case of operational problems, disconnect your unit by removing the modular
plug from the telco jack.  If your regular phone (or other device or system) still
works properly, your DC-8 Plus has a problem and must remain disconnected and
officially serviced or returned for repairs.  If upon the above disconnection, your reg-
ular service still has problems, notify your telephone utility company that they may
have a problem.  Request prompt service at no cost to you the user.  If a problem is
found in premises wiring not telco-installed, you are subject to a service charge.  If
a fault is in telco installed wiring, you may not be subject to a service charge.

6.  Unless otherwise noted in the User’s Manual (e.g.: fuses, etc.), user may not
under any  circumstances (in or out of warranty) attempt any service, adjustments or
repairs on this unit (NO USER SERVICEABLE PARTS).  It must be returned to
Broadcast Tools, Inc. for all such work.  Broadcast Tools, Inc. address and phone
information is listed on page 3 of this manual.  

7.  Special FCC rules apply to equipment connected behind a PBX or KTS.

NOTE:

Items above flagged
with * are noted in this
manual and on the
equipment’s FCC
Compliance label.

Summary of Contents for DC-8 Plus

Page 1: ...Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tools Inc All...

Page 2: ...anual Table of Contents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 FCC Notice 4 General Description 5 Additional Features 5 Typical Applications 5 Installing the...

Page 3: ...t or you need assistance please con tact your distributor from whom you purchased this equipment If you would like more information about Broadcast Tools products you may reach us at Broadcast Tools I...

Page 4: ...ion of your equipment provided you are given adequate advance written notice to permit correct operation 5 In case of operational problems disconnect your unit by removing the modular plug from the te...

Page 5: ...e acknowledgment defeat May be configured for stand alone DTMF tone decoding On power loss and restoration all relays retain their prior state Each relay may be configured to close for as long as the...

Page 6: ...alent is also suggested for the power transformer while the Tripp Lite DTEL 2 is very effective for the tele phone line The purchase of an inexpensive uninterruptible power sup ply UPS will provide ba...

Page 7: ...rol has a range of 4 dbu to OFF The balanced Auxiliary input is labeled AUX and AUX and feeds the DTMF decoder directly and may be adjusted by the AUX control on the rear panel The telephone hybrid nu...

Page 8: ...elay contact enter the star key relay number and the star key Performing this function will return the appropriate relay to an off or unlatched mode If you have selected the interlock mode only one re...

Page 9: ...r need be entered In the event you would like the call back number to be displayed on a digital pager enter 97 followed by the return call back number that will dis play on the pager The DC 8 Plus wil...

Page 10: ...ing NO access code Audio ON Auto coupler mode 900 Mode 901 off Default 911 Turns relay INTERLOCK mode ON ONE latched relay ON at a time 910 Turns relay INTERLOCK mode OFF Default 92xx Number of rings...

Page 11: ...umber ONE to dial Up to 20 digits 1 second pause Default NO number Example 96112069384433 962x x Telephone number TWO to dial Up to 20 digits 1 second pause Default NO number Example 96212069384433 96...

Page 12: ...beep is sent K1 closes for 1 2 second No tone is recorded STOP When key 2 is released K2 closes for 1 2 second and then the double acknowledgment beep is sent Note A good number of systems stop the re...

Page 13: ...ugh 8 follow the listed steps below Jumper Status inputs one and two to the DGND terminals Connect the audio output of the device to be monitored to the AUX input terminals Connection to the phone lin...

Page 14: ...sceiver Relays OC Sealed relays 6 SPDT 2 2PDT Bifurcated Crossbar silver alloy with gold overlay contacts 30 vdc 750 ma Open collector Ground Sink 24 vdc 100 ma NOTE For safety do NOT connect 120VAC c...

Page 15: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLI...

Page 16: ...e mail support broadcasttools com voice 360 854 9559 fax 360 854 9479 DC 8 Plus Installation and Operation Manual 16 APPENDIX...

Reviews: