e-mail:
voice:
360.854.9559
fax:
866.783.1742
17
Audio Sentinel Installation and Operation Manual
OPERATION
Update Interval (Hours): This determines how often an update email is sent.
Only devices enabled for logging will be included in
this email. If set to 0 (zero), no logging email will be
sent. Default: 0
“Alarm” Recipient Addr: Email Recipient 1, Email Recipient 2, Email Recipient
3, Email Recipient 4
SNMP Manager IP Addr:
This is the IP address of the SNMP manager. The sys-
tem only accepts SNMP requests from this IP address,
and will send traps to this IP address only.
SNMP Manager Trap Port: This is the port number that SNMP trap messages will
be sent.
SNMP Read Community: This is the community name for Read-Only access.
SNMP Write Community: This is the community name for Read-Write access.
SNMP Enable Traps:
When checked, trap messages will be sent, when
unchecked no trap messages will be sent.
NOTE: A cold-start trap will be sent when the unit boots up if the SNMP
Enable Traps is checked, otherwise trap messages are sent based on the device
and enabled alarms.
NTP Server Address:
Enter the NTP address here.
Default: pool.ntp.org
NTP Port:
Normally 123.
Default: 123
NTP Update Interval (Min): Time between timing updates. Default: 30
NTP Enabled:
Must be enabled for correct timing.
Default: Enabled
Site ID:
This is the Site Identifier that will be sent in each email.
Monitor Refresh Time (Sec): How many seconds the Monitor page refreshes, short-
er times may increase network traffic.
Time Zone Offset frm UTC: Must be set for correct timing. Default: -8
WEBSITE:
Visit our web site for
product updates and
additional information.