66
©2020 Broadcast Electronics
5.
Preset
Provides a secondary APC setpoint for setting power to a
lower power level. When Preset is Enabled the setpoint
is for the Preset APC setpoint
6.
System Block Diagram
Overall system status. Green, amber, and red block
colors correspond to front panel LED behaviors. See
section 5 Front Panel Features for details.
7.
Power Control Set Point
Forward power value that automatic power control
attempts to converge to. Note that exciter setups do not
rely on this. External power control from a transmitter is
utilized instead.
8.
Forward Power
Internally measured system forward RF power output
reading.
9.
Reflected Power
Internally measured system reflected RF power reading.
10.
Frequency
FM carrier frequency setting.
11.
Modulation
Internal frequency modulation peak hold as a
percentage of peak deviation from nominal frequency.
12.
Fault/Alarm
System faults cause this to display red, and alarms in the
system cause this to display amber. Check the Logs page
for details.
Block Diagram used for Navigation
In any of the System Block Diagrams, many of the block figures will also provide navigation to the
screen represented by the figure
Power Amplifier
The power amplifier page contains detailed status information for all power amplifiers in the system. In