Commissioning
B115 06/16 Rev.2
ZIRKON D060 D – D140 D
15
1.
The connection for pressure conduit, figure 4, position 5.
The compressed air is channeled through the connection in the pressure
conduit and fed to the generator.
INFORMATION!
With too narrow and/or long conduits the output of the machine is reduced!
2.
The electrical data is indicated on the type plate (position 8) or on the motor
type plate. The motors conform to DIN EN 60034 and are displayed in
Safety type IP 55 and isolation class F. The corresponding connection
scheme is displayed in the junction box of the motor (not present where the
circuit has a plug connection). The motor data should be compared with the
existing grid (current type, tension, grid frequency and permitted current
strength).
For information regarding single-phase and triple-phase alternating current
as well as connection setting see below!
3.
The motor and motor protection switch (for security a motor protection
switch and for draught exclusion of the connecting cable a cable threading
are provided).
INFORMATION!
We recommend the use of motor protection switches where switching off is
dependent upon a possible excess current which becomes time-delayed.
Short-term excess current can occur during a cold start of the compressor!