Brivo ACS300 Installation Manual
© 2019 Brivo Systems LLC. All rights reserved.
P-MAN-PUB-Brivo ACS300 Installation Manual
22
a)
Use the wire recommended by the manufacturer of the reader or keypad. If no wire is
recommended, use a minimum of 22 AWG wire with sufficient conductors that include
shield (drain).
b)
If your reader interfaces use standard Wiegand conventions, connect the wire properly
to the terminal block on the appropriate board node. Following is a typical,
but not
universal
, wiring guide. Refer to the Approved Wiegand and OSDP Reader List for
guidelines related to your specific reader or keypad.
•
Connect the green reader wire to the DATA0 terminal. This is the standard
Data 0 circuit for Wiegand readers.
•
Connect the white reader wire to the DATA1 terminal. This is the standard
Data 1 circuit for Wiegand readers.
•
Connect the black reader wire to the GND terminal. This is the standard
Ground circuit for the reader.
•
Connect the blue or yellow reader wire to the BUZZ terminal. This is the
standard Buzzer circuit for the reader.
NOTE:
In regards to the BUZZ terminal, please consult the
manufacturer’s wiring
instructions to determine the color of the wire.
•
Connect the red reader wire to the 12VDC terminal. This pr12VDC
to power the reader.
•
Connect the orange reader wire to the GRN LED terminal. This is the green
LED circuit.
•
Connect the brown reader wire to the RED LED terminal. This is the red
LED circuit.
c)
If your reader is OSDP using RS-485 wiring conventions, connect the wire properly to the
terminal block on the appropriate board node. Following is a typical,
but not universal
,
wiring guide. Refer to the Approved Wiegand and OSDP Reader List for guidelines
related to your specific reader or keypad.
•
Connect the wire to the RXD+ terminal. This is the standard RXD+ circuit
for OSDP readers using RS-485.
•
Connect the wire to the RXD- terminal. This is the standard RXD- circuit for
OSDP readers using RS-485.
•
Connect the wire to the GND terminal. This is the standard Ground circuit
for the reader.
•
Connect the wire to the 12VDC terminal. This pr12VDC to power
the reader.