Brivo ACS300 Installation Manual
© 2019 Brivo Systems LLC. All rights reserved.
P-MAN-PUB-Brivo ACS300 Installation Manual
13
OPTIONAL: If not using Power over Ethernet, wire the DC transformer to the power supply
WARNING: Transform Connection
DO NOT CONNECT THE TRANSFORMER TO A SWITCHED OUTLET OR OTHERWISE
CONTROLLED AC OUTLET.
DO NOT CONNECT THE TRANSFORMER TO THE 120 VAC OUTLET UNTIL ALL
WIRING IS COMPLETED.
1.
Use 18 AWG wire (minimum grade) to connect the screw terminals on the transformer to the
POWER INPUT terminal block on the ACS300, using terminals DC +/AC1 and DC -/AC2.
Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL294/B.
Connect AC Transformer to Power Supply
Model
Circuit
Voltage (VDC)
Current (A)
Brivo ACS300-A/E
Input
12VDC
2.5 A