Brivo ACS300 Installation Manual
© 2019 Brivo Systems LLC. All rights reserved.
P-MAN-PUB-Brivo ACS300 Installation Manual
14
POWERING AND TESTING PROCEDURES
WARNING: Power Precautions (if not using Power over Ethernet)
CHECK THE FOLLOWING CONNECTIONS AND MAKE SURE THAT:
•
The transformer is NOT plugged into the 120 VAC outlet.
Power up the ACS300
1.
Plug the CAT 5 cable into the LAN/PoE connector.
2.
Check ALL power indicators:
a)
Check the ACS300 to confirm that the green power rail LED lights are on, indicating that
AC power is being supplied to the board and that the board is producing 12 VDC power.
b)
Check the ACS300 to confirm that the Health and Connect Status Lights have come on.
ACS300 Health and Connect Status Lights and Diagnostic LEDs
Front Panel
Meaning
Health
Connect
Mostly Solid
(Slow blink every 15 seconds)
Solid
Unit is healthy and connected to host
server
Mostly Solid
(Slow blink every 15 seconds)
Off
Unit is healthy but not connected to host
server
Blinking
Solid
Unit not healthy
Blinking
Blinking
Unit not healthy and not connected to
host server
Off
Off
No Power
ACS300 Panel Light Indicators
c)
If any of the power indicators are not correct (i.e., the green power rail LED lights do not
come on or the blue Health and Connect LEDs do not begin blinking, check the
connections from the ACS300 to the network connection. If all connections are good but