background image

Indicators on LCD

Transmission Indicator

Temperature / Timer display

Fan speed display

Silence Display

Sleep Display

Mode display

ON / OFF display

This transmission indicator illuminates when the
remote control transmits a signal to the indoor unit.

Displays the current operation mode. Including
auto(

), cool(

), dry(

), heat(

), fan(

)

and back to auto (

).

Displays the temperature setting (17 C ~ 30 C). When

O

O

you set the operating mode to FAN, no temperature
setting is displayed. If in the TIMER mode, it will
show the ON and OFF settings of the TIMER.

Displayed by pressing the ON / OFF button.
Press the ON / OFF button again to change.

Displays the selected fan speed, AUTO (no display)
and three fan speed levels " " (LOW) "

" (MED)

"

" (HIGH) can be indicated. The fan speed is AUTO

when the operating mode is either AUTO or DRY.

Displayed when SILENCE function is activated.

Displayed during SLEEP mode.
Press the SLEEP button again to exit SLEEP mode.

Note:

All indicators shown in the figure are for the purpose
of presentation. During the actual operation of the
remote control, only the relative functional signs are
shown in the display window.

Lock Display

Displayed when LOCK mode is activated.

FOLLOW ME Display

Displayed when FOLLOW ME function is activated.

auto cool dry

heat

fan

silence sleep follow me lock

run

SET TEMP. TIMER ONOFF

System operation

Cooling /Heating/Fan operation

Ensure the unit is plugged in and the power is
turned on.
1. Press the

button to select COOL,

MODE

HEAT or FAN mode.

2. Press the

buttons to set the

UP / DOWN

desired temperature. The temperature can
be set within a range of 17 C ~ 30 C in 1 C

O

O

O

increments.

3. Press the

button to select the fan speed

FAN

in four steps - Auto, Low, Med or High.

4. Press the

button to start the air

ON / OFF

conditioner.

In FAN mode, the temperature setting is not
displayed on the remote control; you are unable
to control the room temperature. In FAN mode,
only steps 1, 3 and 4 may be performed.

NOTE

Auto operation

Ensure the unit is plugged in and the power is
turned on. The OPERATION indicator on the
display panel of the indoor unit will start flashing.
1. Press the

button to select Auto.

MODE

2. Press the

button to set the

UP / DOWN

desired temperature. The temperature can
be set within a range of 17 C ~ 30 C in 1 C

O

O

O

increments.

3. Press the

button to start the air

ON / OFF

conditioner.

1. In Auto mode, the air conditioner will logically

choose Cooling, Fan, or Heating mode by
sensing the difference between the actual
ambient room temperature and the set point
temperature on the remote control.

2. In the Auto mode, you can not control the fan speed.

It is automatically controlled by the unit.

3. If the Auto mode is not comfortable for you, set the

desired mode manually.

NOTE

3

1

2

4

1

2

3

2

2

TURBO

SELF

CLEAN

SLEEP

FRESH

SILENCE

TIMER

ON

TIMER

OFF

LOCK

RESET

LED

FOLLOW

ME

FAN

SPEED

SWING

MODE

TEMP

ON/OFF

ON/OFF

SWING

TURBO

SELF

CLEAN

SLEEP

FRESH

SILENCE

TIMER

ON

TIMER

OFF

LOCK

RESET

LED

FOLLOW

ME

FAN

SPEED

SWING

MODE

TEMP

SWING

Summary of Contents for RG36F/BGCEF

Page 1: ...manual carefully before operation and retain for future reference To be read in conjunction with the User Manual accompanying the Air Conditioner Due to our policy of continuous improvement product specifications and details are subject to change without notice Please contact Brivis on 1300 BRIVIS 1300 274847 or visit brivis com au for further information ...

Page 2: ...ol to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote control either move these appliances or consult your installer CAUTION Do not mix old and new batteries or batteries of differ...

Page 3: ...it is running in SLEEP mode this function will be cancelled if you press the MODE FAN SPEED or ON OFF button 6 Activate Disable SLEEP function If this button is held for more than 2 seconds the FRESH function will be activated Press and hold for more than 2 seconds again to disable SLEEP FRESH optional Button SWING Button SWING Button Used to stop or start the horizontal louver movement or set the...

Page 4: ... frequency and the indoor fan will be set to low speed This will reduce the noise levels to their lowest and create a quiet and comfortable room for you Due to low frequency operation the unit may be unable to cool or heat the room effectively 14 15 LOCK Button When you press the recessed LOCK button all current settings are locked in and the remote control does not accept any other commands excep...

Page 5: ...and the power is turned on 1 Press the button to select COOL MODE HEAT or FAN mode 2 Press the buttons to set the UP DOWN desired temperature The temperature can be set within a range of 17 C 30 C in 1 C O O O increments 3 Press the button to select the fan speed FAN in four steps Auto Low Med or High 4 Press the button to start the air ON OFF conditioner In FAN mode the temperature setting is not...

Page 6: ...on Timer operation Press the TIMER ON button to set the auto on time of the unit Press the TIMER OFF button to set the auto off time of the unit 1 Press the TIMER ON button The remote control will display TIMER ON the last Auto on setting time and the signal H will be shown in the LCD display area Now the unit is ready to reset the Auto on time to the start time 2 Push the TIMER ON button again to...

Page 7: ...op automatically at the set time To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of the stop operation time and the signal H will show in the display area 2 Press the TIMER OFF button to display 10H in the TIMER OFF display of the remote control 3 Wait for approximately 2 seconds and the digital display area will show the temperature again The TIMER OFF indica...

Page 8: ...e most comfortable temperature and save energy NOTE The SLEEP function is only available under Cooling Heating and AUTO operations 1 2 1 TURBO SELF CLEAN SLEEP FRESH SILENCE TIMER ON TIMER OFF LOCK RESET LED FOLLOW ME FAN SPEED SWING MODE TEMP SWING TURBO SELF CLEAN SLEEP FRESH SILENCE TIMER ON TIMER OFF LOCK RESET LED FOLLOW ME FAN SPEED SWING MODE TEMP SWING LED FOLLOW ME function Press this but...

Reviews: