Model

Rated Voltage

8m

3.0V (2 x AAA 1.5Volt Batteries)

Remote Control Specifications

1. Operating Mode: AUTO, COOL, DRY, HEAT and FAN.
2. Timer Setting Function in 24 hours.
3. Indoor Setting Temperature Range: 17 C ~ 30 C

0

0

4. Full function LCD (Liquid Crystal Display).

Environment

Signal Receiving
Range

Performance Feature

RG36F/BG(C)EF, RG36F1/BG(C)EF

Model A:RG36F/BG(C)EF

-5 C ~ 60 C

0

0

NOTE:

utton design

be slightly different from the one

Remote control b

may

epending on

individual model.

supplied d

the

All the functions described are

.

associated with the relative indoor unit

If the indoor unit

feature, there is no

does not have a particular

performed by the indoor unit

corresponding operation

.

1

2

4

5

3

9

10

8

6

7

11

12

13

14

15

TURBO

SELF

CLEAN

SLEEP

FRESH

SILENCE

TIMER

ON

TIMER

OFF

LOCK

RESET

LED

FOLLOW

ME

FAN

SPEED

SWING

MODE

TEMP

ON/OFF

SWING

Function buttons

1

2

Each time the button is pressed, the operating
mode is cycled in the following sequence:

3

MODE Button

4

5

ON/OFF Button

Operation starts when this button is pressed
and stops when this button is pressed again.

AUTO

COOL

DRY

HEAT

FAN

NOTE:

If the unit is running in SLEEP mode, this

function will be cancelled if you press the MODE,
FAN SPEED or ON/OFF button.

6

Activate / Disable SLEEP function. If this button
is held for more than 2 seconds, the FRESH
function will be activated. Press and hold for
more than 2 seconds again to disable.

SLEEP / FRESH (optional) Button

SWING

Button

SWING

Button

Used to stop or start the horizontal louver
movement or set the desired up / down air flow
direction. The louver changes in 6 angle

0

increments with each press. If the button is held
for more than 2 seconds, the louver will swing
up and down automatically.

Activate / Disable TURBO function. Press and
hold for more than 2 seconds to activate the
SELF CLEAN function. Press and hold for more
than 2 seconds again to disable.

TURBO / SELF CLEAN Button:

Used to stop or start the vertical louver
movement or set the desired left / right air flow
direction. The louver changes 6 angle

0

increments with each press. And the temperature
display area of indoor unit displays

for one

second. If the button is held for more than
2 seconds, the louver will swing left and right
automatically, and the display area of indoor unit
will flash ‘III’ four times. The display will then revert
back to the temperature setting. If the vertical louver
swing feature is stopped, the display will show ‘LC’
for 3 seconds.

,

,

Summary of Contents for RG36F/BGCEF

Page 1: ...manual carefully before operation and retain for future reference To be read in conjunction with the User Manual accompanying the Air Conditioner Due to our policy of continuous improvement product specifications and details are subject to change without notice Please contact Brivis on 1300 BRIVIS 1300 274847 or visit brivis com au for further information ...

Page 2: ...ol to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the sunlight from falling on the receiver If other electrical appliances react to the remote control either move these appliances or consult your installer CAUTION Do not mix old and new batteries or batteries of differ...

Page 3: ...it is running in SLEEP mode this function will be cancelled if you press the MODE FAN SPEED or ON OFF button 6 Activate Disable SLEEP function If this button is held for more than 2 seconds the FRESH function will be activated Press and hold for more than 2 seconds again to disable SLEEP FRESH optional Button SWING Button SWING Button Used to stop or start the horizontal louver movement or set the...

Page 4: ... frequency and the indoor fan will be set to low speed This will reduce the noise levels to their lowest and create a quiet and comfortable room for you Due to low frequency operation the unit may be unable to cool or heat the room effectively 14 15 LOCK Button When you press the recessed LOCK button all current settings are locked in and the remote control does not accept any other commands excep...

Page 5: ...and the power is turned on 1 Press the button to select COOL MODE HEAT or FAN mode 2 Press the buttons to set the UP DOWN desired temperature The temperature can be set within a range of 17 C 30 C in 1 C O O O increments 3 Press the button to select the fan speed FAN in four steps Auto Low Med or High 4 Press the button to start the air ON OFF conditioner In FAN mode the temperature setting is not...

Page 6: ...on Timer operation Press the TIMER ON button to set the auto on time of the unit Press the TIMER OFF button to set the auto off time of the unit 1 Press the TIMER ON button The remote control will display TIMER ON the last Auto on setting time and the signal H will be shown in the LCD display area Now the unit is ready to reset the Auto on time to the start time 2 Push the TIMER ON button again to...

Page 7: ...op automatically at the set time To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of the stop operation time and the signal H will show in the display area 2 Press the TIMER OFF button to display 10H in the TIMER OFF display of the remote control 3 Wait for approximately 2 seconds and the digital display area will show the temperature again The TIMER OFF indica...

Page 8: ...e most comfortable temperature and save energy NOTE The SLEEP function is only available under Cooling Heating and AUTO operations 1 2 1 TURBO SELF CLEAN SLEEP FRESH SILENCE TIMER ON TIMER OFF LOCK RESET LED FOLLOW ME FAN SPEED SWING MODE TEMP SWING TURBO SELF CLEAN SLEEP FRESH SILENCE TIMER ON TIMER OFF LOCK RESET LED FOLLOW ME FAN SPEED SWING MODE TEMP SWING LED FOLLOW ME function Press this but...

Reviews: