6
2.2
Location of the Interface Module
The
Interface Module
shall be located within 1.5m of a 10 Amp
240 volt fixed switched socket outlet. The Brivis Touch shall be
within 20m of the
Interface Module
.
2.3
Install the Brivis Touch
The Brivis Touch
Backing Plate
must be installed prior to
mounting the Brivis Touch.
To mount the
Backing Plate
do the following:
1. Remove the Brivis Touch
Backing Plate
from the packaging.
2. Use
Backing Plate
as a template and mark the two
Mounting
Hole
centres and the
Loom Access
hole centre, refer to
Diagram 5.
3. Install the supplied wall
Plug Kit
in the
Mounting Hole
locations. For drill sizes refer to Diagram 5.
4. Fasten
Backing Plate
with wall
Plug Kit
screws.
Diagram 5:
Brivis Touch “
Backing Plate
”
To mount the “Brivis Touch”:
1. Run the supplied
P&C Loom
from the Touch to the
Interface Module
.
2. Draw the loom from the wall cavity and feed through the
P&C Loom Access
opening on the
Touch Backing
Plate
.
3. Connect the
P&C Loom
terminal (female) to the
Touch
terminal (male) before mounting it on the wall, refer to
Diagram 6.
4. Push excess cable back into the wall cavity and mount
Touch
onto the
Backing Plate
. The three
Male Clips
on
the
Backing Plate
will engage and secure the
Touch
,
refer to Diagram 7.
Diagram 6
: Brivis Touch Controller P&C Loom Connection
Mounting Hole
Drill size
ø
6.0mm
Mounting Hole
Drill size
ø
6.0mm
P&C Loom
Access
Drill size
ø
13
2
3
1