15
Diagram 22
: Fan run hour limit
The owner can book a service call or clear the spanner icon
notification by pressing the “Clear
”
button
3.12
Outdoor Temperature Sensor (Optional)
The
Brivis Touch Controller
can display the ambient (outdoor)
temperature.
To enable, install a Brivis NT-1 Remote
Temperature Sensor and set the JUMPER position to “AMB” (see
Diagram 23). Connect the NT-1 to the 2-wire bus (TW1 & TW2).
The most accurate way of reading the ambient temperature is to
install the NT-1 sensor under the eaves on the south side of the
home away from potential heat sources.
4.0
Product and Warranty Registration
Brivis recommends the registration of all products to ensure
efficient product support if and when required. Please inform the
home owner that product registration can be completed either:
on-line at
brivis.com.au
or via the registration form in the product Owner’s Manual (e.g.
Brivis Heater Owner’s Manual)
5.0
Instruct Home Owner on System Operation
System design conditions
MTSP or STSP (if fitted)
Zone identification
Minimum / maximum no. of simultaneous zones for design
conditions for Heating and Cooling
Common Zone operation (if applicable)
Constant Zone operation (if applicable)
Manual Operation
Schedule (Auto) Operation
Diagram 23
: NT-1