2.7
Connection of Interface Module to Appliance
The
Interface Module
has four terminal points for the
connection of the Brivis Appliance control wires TW1 &
TW2. When connecting to an appliance, use only the first
set (Set 1) of two terminals or the second set (Set 2).
Never
use
a mixed
combination
of
terminals
when
connecting to a single appliance. For example, a
Brivis
Touch
operating a Brivis Evaporative Cooler and a Brivis
Gas Heater may have the two right terminals connected
to the Heater (
SET 1
) and the two left terminals connected
to the Evaporative Cooler (
SET 2
), refer to Diagram 11.
Diagram 11
: Connection of Interface Module to Appliance
For more information regarding appliance connection please
refer to the product installation manual supplied with the
appliance.
3.0
System Setup
3.1
Turning the System ON
Once the system is fully connected, it can now be turned ON in the
following sequence:
1. Mains power to heater
516 Zone Module
(if connected).
2. Mains power to Heater / Evaporative Cooler / Refrigeration
appliance(s).
3. Mains power to
Interface Module.
Press isolation switch on
Interface Module
(L.E.D on).
Once completed the Brivis Touch Controller will power up and you
will be prompted to enter the day and time.
Note:
When there is more than one Brivis appliance connected to
the
Interface Module
ensure that the TW1 & TW2 polarity is
correct at both ends of the 2-wire bus cable.
Note:
Do not install any wiring with the power turned on, as the
fuse may blow, which would not be covered under warranty.
TW1
TW2
TW1
TW2
To Heater
To Evaporative
Cooler
SET 2
SET 1
Note
: Once you access the MENU Screen and select a
configuration option, if no button is pressed for 60 seconds while
in that configuration screen, the Touch will exit the configuration
mode and return to normal operation; this applies to all options
other than SCHEDULE.