Measured CCT >4400K:
press to encoder to adjust the CW-value and turn the
encoder to reduce the CW-value until CCT = 4400K.
•
When ready: press the [ENTER]-button to save the new values.
ELECTRICAL INSTALLATION
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for two or more units in DMX-mode:
•
The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
“daisy chain” your DMX controller and all the connected units.
•
Pin layout XLR-3pin: Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
•
To prevent strange behavior of the light effects, due to interferences, you must use a
90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this simply
won’t work!
•
Make sure that all units are connected to the mains.
•
Each unit in the chain needs to have its proper starting address so it knows which
commands from the controller it has to decode.
•
Electrical installation for two or more units in WIRELESS DMX:
Same procedure as for a standard DMX-setup but 2 possibilities:
•
Pure W-DMX:
all projectors are equipped with an optional WTR-DMX DONGLE ! (Briteq code: 4645).
The DMX-controller send a WIRELESS DMX-signal to all units.
•
Mixed W-DMX:
the first projector is equipped with an optional WTR-DMX DONGLE ! (Briteq code: 4645).
The wireless DMX-signal sent to the first projector is also available on its DMX-output. All other DMX-
equipment can be connected to the first projector using a standard DMX-cable.