The fi lter system must not be opened or dismantled during operation. The fi lter
•
cartridge must not be opened.
The pressure vessel and pressure vessel lid of the fi lter system are designed for a
•
service life of 10 years (from the date of installation). They must be replaced after
10 years. The hoses must be replaced in rotation after 5 years.
Production date.
•
Production code sticker fi lter cartridge and packaging - Example: B715002010
7
Production year, here: 2007
15
Production week, here: calendar week 15
002
Batch No. fi lter medium, here the second batch fi lled in terms of quantity
010
Serial number of the fi lter cartridge, here the tenth cartridge from the second batch
Production code sticker connector head - Example: 7102 XX
7
Production year, here: 2007
10
Production week, here: calendar week 10
2
Production day from Monday (1) to Friday (5), here: Tuesday
xx
Internal code
Production date pressure vessel and pressure vessel lid - Example: 0307
03
Production month, here: March
07
Production year, here: 2007
3.5 Technical Safety Assembly Instructions
The terminal device operated with the fi lter must be free of limescale prior to
•
installation.
!
Caution:
No water softening system may be operated upstream from
the fi lter system.
Protect the fi lter system from sunlight and mechanical damage. Do not assemble
•
near sources of heat and open fl ames.
A stop valve must be installed before the fi lter system intake hose.
•
If the water pressure is higher than 6 bar, a pressure reducer must be installed before
•
the fi lter system.
A non-return valve tested by the DVGW has been factory-installed at the water intake
•
of the fi lter head.
No copper pipes and no galvanised or nickel-plated pipes/connectors may be
•
installed between the water fi lter and the consumer. The use of Brita hose sets is
recommended here. When choosing the material for parts that come into contact
with water after the BRITA fi lter system it must be remembered that, due to the
process, decarbonised and/or fully demineralised water contains free carbon dioxide.
All parts must be installed in accordance with the country-specifi c guidelines on the
•
installation of drinking water facilities.