Electrical Requirements  

 Important:

 

You must switch off the power at the consumer unit,  

 

 

 

isolate the electrical circuit and verify the earth before  

 

 

 

making any electrical connections.

The Mixing Valve must only be connected to a 230-240V AC supply. This product  
must be connected to a fused spur with double-pole isolation and a 3A fuse.

It is recommended that a residual current device (RCD) formerly known as an earth 
leakage circuit breaker (ELCB) with a tripping current of 30mA, incorporated in the 
circuit. This may be part of the existing consumer unit or a seprate unit.

For close circuit protection 

DO NOT

 use a rewireable fuse. Instead use a suitably 

rated miniature circuit breaker (MCB) or Cartridge Fuse.

Do not turn on the electrical supply until the plumbing has been completed and the 
Mixing Valve cover re-fitted (if removed).

Installation

Fixing the Mixing Valve to the 

floor/wall 

 
 
 
 
 
 
Please refer to ‘Positioning the Mixing 
Valve’ on before starting any installation.

The Mixing Valve needs to be installed 
on either a flat floor or a wall surface.

Position the Mixing Valve on the floor or 
wall surface and mark all 4 fixing points.

Fixing Points

IMPORTANT

Prior to drilling 

check ther

are no hidden 

electrical cables 

or water supply 

pipes

Need help? 

Give us a call on 

0330 026 6273 

and speak to one of our trained advisors.  

9

Installation Requirements

Summary of Contents for Artisan Evo

Page 1: ...and User Guide Artisan Evo Digital Electronic Mixer Shower Models Covered ARDE SHCDIVM C Please keep this booklet for future reference Installer when you have read these instructions please ensure yo...

Page 2: ...ing a contemporary design wireless electronic controller and digital mixing unit Bristan s Digital Electronic Mixer Shower has been designed to be easy to install and use It has also been designed and...

Page 3: ...order to remove any remaining swarf solder etc Failure to carry out this procedure could cause problems or damage to the workings of the Mixing Valve Do not operate the shower if the water stops flowi...

Page 4: ...been tested to the Water Regulations Advisory Scheme WRAS and satisfies the requirements of the Water Supply Water Fittings Regulations 1999 and current bylaws For full Installation Requirements Notes...

Page 5: ...ital display screen Displays the water temperature Any error codes will be displayed on here 5 Time out mode If the shower has been running for 30 minutes the Mixing Valve will automatically shut off...

Page 6: ...ntation of the Mixing Valve The Mixing Valve can be installed in either an airing cupboard loft space or under the bath Do not site the Mixing Valve where it may be subjected to freezing conditions or...

Page 7: ...at its outlet discharges above the spill over level of any appliance as indicated on the illustration below Wireless Installation Considerations As with any wireless radio product Metallic lined mater...

Page 8: ...a WC then the air gap should be a type AUK3 not less Electrical Requirements Warning This appliance MUST be earthed Power Rating 230V AC 35W The Electricical Installation and Curcuit Protection of th...

Page 9: ...ose circuit protection DO NOT use a rewireable fuse Instead use a suitably rated miniature circuit breaker MCB or Cartridge Fuse Do not turn on the electrical supply until the plumbing has been comple...

Page 10: ...End Negative Head Pump ST NHPUMP 18TN Pump installation must be in accordance with the Fitting Instructions supplied with the pump The Negative Head Pump is required to maintain the 0 5 bar minimum st...

Page 11: ...lied should be installed in the supply circuit This may be part of a consumer unit or a separate unit Wiring of Connection Unit Warning This appliance must be earthed The wires in the mains lead are c...

Page 12: ...ehind the fixing bracket Once the wall bracket is secured to the wall surface turn the locking ring so that one of the four fixing lugs is at a 12 o clock position Fit the remote control onto the lock...

Page 13: ...ll Screw the shower rose on to the arm ensuring the washers are in place Connect the hose to the handset and place in the slider Your shower is now ready to be commissioned for first use Screw the hos...

Page 14: ...mixing valve For the wireless communication to work the Remote Control needs to be initialised and paired with the Mixing Valve This is pre configured upon manufacturing of the product so the product...

Page 15: ...hange the number until 2 is displayed The 2 will stay displayed for 2 seconds and then change to a flashing 0 2 4 Press the Temp up button ten times to increment the flashing number from 0 to 9 and th...

Page 16: ...12 seconds 7 Once the pulsing stops turn the Controller Off 8 To resume normal showering simply turn the Controller on as normal 46 C SW1 1 ON SW1 2 ON SW1 3 OFF 48 C SW1 1 OFF SW1 2 OFF SW1 3 ON Once...

Page 17: ...e ensure the commissioning procedure has been carried out If you did not fit this shower yourself and you are about to use it for the first time check with the installer to ensure they have run the co...

Page 18: ...w High Flow Memory Button E Memory Function Only available on Chrome variants The Memory Function allows the user to store Temperature and Flow pre sets and recall them to set the shower to their desi...

Page 19: ...perature and Flow regardless of the actual position of the lever to the stored settings The Shower s Temperature and Flow can be adjusted in the normal way using the Temperature buttons and Flow lever...

Page 20: ...er washers Re fit the inlet connections ensuring they are fully tightened Filter Washer Insert NRV Battery Replacement The Wireless Controller is powered by two AA batteries which are designed to last...

Page 21: ...ispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The seperate collection and recycling of your waste eq...

Page 22: ...sure refer to Specification for working pressures Mixing Valve is excessively noisy Purging procedure was not carried out when commissioning the Mixing Valve Purge the Mixing Valve Refer to Purge Proc...

Page 23: ...rm Shower Arm x1 1 06 81P13700 000 001 Shower Rose Shower Rose x1 1 07 82M50020 0350CA1 Slider Slider x1 1 08 HAND22 C Handset Handset x1 1 09 HOS 125CN01 C 1 25m Shower Hose Hose x1 1 10 32C00051 ASS...

Page 24: ...our products effective from the date of purchase to give you peace of mind To start your free guarantee simply scan the QR code and register your product Alternatively visit www bristan com register...

Reviews: