Specifications
Inlet Connections: 15mm compression with 150mm between centres.
Minimum working pressure: 0.2 bar
Note: This product has been designed to deliver a high flow of water on low pressure
systems, however, depending on the installation, type of system and shower
accessories, a higher pressure maybe required to optimise the showering experience.
Maximum working pressure: 5.0 Bar
Maximum static pressure: 10 Bar
Note: Static pressure is the build up of pressure when the valve is closed.
Supply Requirements:
Minimum cold water supply temperature: 5°C
Maximum cold water supply temperature: 25°C
Maximum hot water supply temperature: 80°C
Note: The inlet hot water temperature must be at least 10°C above the required blend
temperature (e.g. shower temperature 43°C: minimum hot water temperature 53°C).
System Requirements:
Gravity fed hot & cold (equal pressures)
Gravity fed hot & mains cold (differential pressure, maximum ratio 5:1)
Unvented systems
Instantaneous water heater (Combination boiler)
Pumped system
Note: When using a pumped system we recommend that an essex flange is used.
Important: Minimum wall cavity depth: 35mm
Min. – Max. concealing plate thickness: 45 – 75mm
For full dimensional drawings please visit: www.bristan.com
Need Help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.