Adjusting the Temperature
The shower valve has been factory set
to 42ºC with equal (balanced) hot and
cold water supply pressures, with the
hot water supply at 65ºC.
If your operating conditions are
different from those above, the
outlet water temperature may
differ from the factory setting.
If required the shower valve can be
re-calibrated to suit your own
temperature requirements.
Set the temperature control to
the maximum setting and
check the
temperature of the water with a
thermometer. If the temperature is
not correct, re-calibrate the shower
valve:
1.Remove the temperature handle but
do not remove the plastic temperature
stop.
2.Turn the spline clockwise to
decrease the temperature and anti-
clockwise to increase the
temperature. Check the temperature
and adjust until you achieve the
required temperature.
3.Replace the temperature
handle ensuring it is fitted back
into the maximum position.
Temperature
Stop
(Do not remove)
Spline
Colder
Adjusting the Temperature
Hotter
Need Help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.