TLC40+50 Eco_v01_GB_NL
10
10 Servicing and Calibration
10.1
Although it is not regarded as necessary for routine cleaning, the heater enclosure may be safely removed
to allow the heater and fan to be dusted.
Disconnect the power lead
. Remove the water pan. Loosen the
4 cap-head screws (on top of the white plastic cabinet, not the grey control box) as shown and then finally
remove each one
while supporting the metal enclosure inside
. The metal enclosure will fall if not held
and may damage the brooder.
10.2
Carefully place the brooder on its top and then lift out the metal heater enclosure. The fan assembly may
then be hinged over toward the front of the machine so that the heating element and fan blades may be
dusted with a soft brush.
USE NO LIQUIDS. DO NOT DISTURB THE TEMPERATURE SENSOR
.
10.3
Once the heater area has been dusted the fan assembly must be relocated by ensuring the 4 pegs on the
clear moulding fit into the corresponding holes in the metal base plate.
10.4
ENSURE THE FAN / LED WIRES ARE NOT TOUCHING THE HEATING ELEMENT
10.5
Replace the metal cover so that the water pan slots are at the correct end. Hold the cover in place and fit
the 4 cap-head screws. Do not over-tighten.
DO NOT DISTURB SENSOR
Fan assembly may be hinged out
on its cables to allow fan and
heater to be dusted with a soft
brush
Fan assembly is located by 4 pegs
in the feet of the clear moulding