11 Hatching
11.1
If hatching in the Mini EX remove the egg disc two days before the hatch is due.
11.2
Turning must be switched to OFF in the control menu.
11.3
Eggs nearing hatch are slightly less sensitive to temperature variation and the hatching temperature can be
reduced by up to 1°C (2°F) but this is not essential.
11.4
Hatching humidity levels need to be high (see section 8 above).
11.5
When most eggs have hatched (12 to 48 hours after the first egg hatches) remove the hatchlings to a
brooder. The Brinsea Cosylamp is ideal for poultry and waterfowl etc. The Brinsea TLC-4 Brooder is
recommended for exotics.
11.6
During hatching the high humidity levels will fall dramatically when the lid is lifted and will take some
time to build up. Resist the temptation to open the incubator frequently – leave for at least 6 hours
between inspections.
12 Cleaning Up
IMPORTANT:
DISCONNECT THE INCUBATOR FROM THE MAINS POWER SUPPLY DURING CLEANING.
ENSURE THAT ALL ELECTRICAL PARTS ARE KEPT DRY. DO NOT IMMERSE THE INCUBATOR
TOP.
12.1
NEVER WASH THE BASE, EGG DISCS, COVERS OR CABINET PARTS IN LIQUIDS OVER 50°C
(120°F). DO NOT USE A DISHWASHER TO CLEAN EGG DISCS, INCUBATOR BASE OR LID.
Following each hatch in the Mini EX remove and wash the egg disc and base in Brinsea Incubation
Disinfectant Solution. Wipe all other internal surfaces with a soft cloth soaked in the solution. Ensure that
the instructions supplied with the fluid are followed.
12.2
Be sure to clean the air vent holes to keep them clear. There are two small holes on the bottom “skirt” of
the lid and one on the back of the clear part of the lid above the level of the fan cover.
12.3
If a separate hatcher is used the procedure above should still be followed every two months.
12.4
Periodically unscrew the four screws retaining the fan cover, remove the cover and soak. Dust and fluff
may be removed from the fan and heater cord with a soft brush. USE NO LIQUIDS. DO NOT TURN
THE LID OVER AS THE FAN IS NOT FIXED ONCE THE FAN COVER IS REMOVED. The fan
should be located on the 4 pegs under the lid before the cover is re-fitted.
THE INCUBATOR MUST NOT BE USED WITHOUT THE FAN COVER FITTED. THE
COVER SUPPORTS THE FAN AND PROVIDES PROTECTION FROM THE MOVING
BLADES.
12.5
The exterior of the incubator and humidity pump may be cleaned with a damp cloth. Avoid allowing any
moisture to get inside electrical housings.
12.6
ALWAYS CLEAN THE INCUBATOR BEFORE STORAGE AND ENSURE THAT THE UNIT IS
TOTALLY DRY INSIDE AND OUT. ALLOW IT TO RUN FOR 24 HOURS WITH NO WATER IN
TO ENSURE IT IS THOROUGHLY DRY.