Renovent Excellent P300 Rev. D
11
A
A
B
X
²
²
²
²
A
²
²
A
t
60 mm
B
t
A
,
,,
/,
,,,
²
²
Chapter 5 Installation
$UUDQJHWKHH[WHULRUDLUVXSSO\IURPWKHVKDGRZHGVLGHRIWKH
dwelling, preferably from the wall or overhang. If the outdoor
air is sucked in from under the tiles, it must be ensured that
no condensation develops in the roof boarding and no water
can run in. Ventilation air can be sucked in from under the
tiles if air can access freely at the top and the bottom of the
roof area and the sewage vent stack does not end under the
tiles.
)HHGWKHH[WUDFWGXFWWKURXJKWKHURRIERDUGLQJLQVXFKD
manner that no condensation develops in the roof boarding.
,QVWDOO WKH H[WUDFW GXFW EHWZHHQ WKH 5HQRYHQW ([FHOOHQW
P300 and the roof sleeve in such a manner that surface
condensation is prevented.
$OZD\VXVHDQLQVXODWHGYHQWLODWLRQURRIVOHHYH
$YRLG WKH XVH RI SHWUROHXPEDVHG DGKHVLYHV LQ DLU SODQW
systems.
7KHPD[LPXPSHUPLVVLEOHUHVLVWDQFHLQWKHGXFWV\VWHPLV
150 Pa at the maximum ventilation capacity. If the resistance
of the duct system is higher, the maximum ventilation
capacity will be lower.
7KH ORFDWLRQ RI WKH PHFKDQLFDO YHQWLODWLRQ RXWSXW DQG
the sewer stack vent relative must be chosen to prevent
nuisance.
&KRRVHWKHORFDWLRQRIWKHVXSSO\YDOYHVWRSUHYHQWIRXOLQJ
and draught. We recommend to use the Brink supply valves.
:KHQPRXQWLQJÀH[LEOHGXFWVEHDULQPLQGWKDWLWPXVWEH
possible to replace them in due course.
,QVWDOOVXႈFLHQWRYHUÀRZRSHQLQJVGRRUJDSFP
A = Spacing 10 mm above roof deck
B = Roof insulation
C = Seal with foam
D = Pipe for make-up air to be carefully insulated and provided
with vapour barrier
1 = Brink supply valves
2 = Supply from wall
3 = Suction valve in ceiling or high in wall
4
= Prevent
crosstalk
5 = Preferably Brink incorporated ducts
a = Gap under the door 2 cm
.
1 = Renovent Excellent P300 left-handed 4/0 (place level)
2 = Preferred ventilation air supply
3 = Ventilation air supply under the tiles
4a = Free suction bottom roof area
4b = Free suction top roof area
5 = Sewer vent
6 = Preferred location extract ventilation air; use Brink
insulated ventilation roof sleeve.
7 = Thermally isolated pipe
8 = Condensate discharge
0XHU
10 = Ducts from and to dwelling