background image

 

32 

 

IR: 

 

 

RS232: 

 

 
 
 
 
 
 

 

Operating Instruction 

Summary of Contents for BL-VWMW-H265-EXT-4K

Page 1: ...1 120M H 265 AV over IP Extender work with CMP System Max resolution 4K 30HZ 4 4 4 Support Video Wall Multi Viewer Matrix Encoder Decoder ...

Page 2: ...ion 8 6 2 2 Login 8 6 2 3 Retrieve the Password 9 6 2 4 Enter CMP System 9 6 3 Add Device Instruction 10 6 3 1 Specific steps 11 6 4 User Management Instruction 21 6 4 1 Create Account 21 6 5 Live Preview Instruction 23 6 6 Basic Instruction 25 6 6 1 Select Language 25 6 6 2 OSD Switch 25 6 7 Video Scheme Instruction 26 6 7 1 Matrix Configuration 26 6 7 2 Screen Divide 27 6 7 3 Screen Splice 28 6 ...

Page 3: ...rix work with CMP system supports real time switch OSD Displaying firmware version IP address MAC address etc Ø Support Multicast one to many many to many Unicast one to one Ø DC12V Power supply 2 Specifications Performance Protocol H 265 Encoder over TCP IP Video format 480P 720P 1080P 4K2K 800 600 1280 1024 60hz etc Audio format Analog Embedded and Analog Extractor Streaming Bit Rate 0 100Mbps D...

Page 4: ...nput Indicator of HDMI LAN Power Reset button DC 12V input Cat5 6 output RS232 pass through HDMI Loop output HDMI Input IR out 4 2 Decoder USB Type A output Analog Output Indicator of HDMI Link Act Power Reset button DC 12V input Cat5e 6 input RS232 pass through HDMI output IR input ...

Page 5: ...rocess description Before connecting the product copy CMP plate setup from the CD double click the software in the installation package to run and install the platform on the computer Take Win7 operating system as an example the installation process is as follows CMP P1 ...

Page 6: ...6 Operating Instruction CMP P2 CMP P3 ...

Page 7: ...7 Operating Instruction CMP P4 CMP P5 ...

Page 8: ...up when it is opened for the first time Enter username password confirmation password and any questions and answers To retrieve the password if you forget 6 2 2 Login After registration the login interface will pop up enter the registered user name and password and you can choose to log in automatically or remember the password Click login to log in to the main interface of the platform ...

Page 9: ...nterface the system will automatically pop up a prompt to retrieve your password You can enter the password retrieval interface enter the answer to the question you filled in during registration and reset your password 6 2 4 Enter CMP System Enter the user name and password correctly and enter the main function interface ...

Page 10: ...CP is ON the router DHCP address pool can automatically assign IP addresses to the product and computer Then the computer can open the software platform to manage and operate To login to the platform for the first time click add device in device management and you can choose to add device quickly automatically scan all devices in the regional network or manually Quick add only need to check add ma...

Page 11: ...to the main interface and click Add Device with the mouse Quick add Click refresh key will automatically search all product IP address in LAN Manually add Enter known IP address protocol TX RX port default username password admin Enter the correct IP address and other parameters by clicking test connection to ensure that the device added is correct ...

Page 12: ...12 Operating Instruction ...

Page 13: ...al IP address will be temporarily invalid reassigned to a new IP address requires the device to be added and the platform will indicate that the device is not online with a dialog box and online status gray means not online and green means online 3 2 Edit Operating Instruction ...

Page 14: ...s admin change the password of the login device and it will take effect immediately after it is confirmed The above change function is only used for the platform when the device is manually added the parameter error can be quickly modified here and the parameter of the device itself cannot be changed 3 2 3 Edit Time Configuration Default check the NTP server synchronization You can check the NTP s...

Page 15: ... video stream otherwise you need to enter account and password when you do not check 4 Default account and password admin Note the modified IP address cannot be the same as the IP address of all connected devices in the network 5 RTSP usage instructions Pre install and open the VLC player download address http www videolan org in the computer then select media open the network streaming as shown i...

Page 16: ...ion the parameters of the main and sub streams can be set as shown in the figure Once the parameter modification is confirmed it can take effect immediately Note these Settings are valid only if the encoding type is set to h 264 Operating Instruction ...

Page 17: ...17 3 2 6 Audio Configuration 3 2 7 OSD Configuration Operating Instruction ...

Page 18: ...18 3 2 8 System Status 3 2 9 Password Configuration Operating Instruction ...

Page 19: ...tate 3 3 0 Reset Device Once the reset device is determined the device will restore factory Settings and all parameters will be restored to the initial state Note if factory Settings are restored the router will reassign the IP address of the product If the original address fails the device should be added again 3 3 1 Reboot Device The parameters previously set will be saved on restart The device ...

Page 20: ... to find the upgrade file bin format and complete the software upgrade after confirmation The platform upgrade device will not change the previous parameter configuration Successful upgrade will be prompted and restart Operating Instruction ...

Page 21: ... user or switch the user to the login screen in the upper right corner of the screen Specific operation steps 1 Open the platform and enter the main function interface 2 Select Create Account fill in new account name and password set account type administrator operator and click confirm 3 Return to the main function interface and click user account and permission 4 Check the list of accounts creat...

Page 22: ...22 Operating Instruction ...

Page 23: ...h between primary and secondary streams 3 Image setting brightness contrast hue saturation 4 Turn on sound and turn off sound 5 Close preview 6 Full screen Specific steps are as follows 1 Open Live preview in the function panel 2 A list of TX device names will be displayed on the left 3 Long press the left button to select a group of devices and drag the current device name into the segmentation b...

Page 24: ...24 Operating Instruction ...

Page 25: ... Chinese and English If the switching is completed the platform needs to be restarted 6 6 2 OSD Switch For large screen segmentation large screen splicing matrix configuration to find RX IP address and other information in order to quickly operate the configuration Operating Instruction ...

Page 26: ...tion 2 The top of the left column represents the preview window and the bottom of the left column represents the TX device list information 3 The middle represents the group channel ID and the right column represents the RX device list information 4 Click any device in the TX list once with the left mouse button and the upper window will take the real time preview image as the current signal sourc...

Page 27: ...ple groups of signal sources are displayed in one screen See the example image below 1 Each group of video sources is presented as a sub stream within the large screen divide 2 Up to 36 groups of signal source segmentation can be supported Operating Instruction ...

Page 28: ...ect the required RX device and long press the left mouse button to drag it into the divide box 7 open the TX device list in the monitoring point area select the required TX device and long press the left mouse button to drag it into the divide box 8 large screen divide operation is completed Note if the RX returns to normal one to many or many to many it can be restored by re entering the matrix c...

Page 29: ...lect the required number of splicing boxes 1 4 16 25 36 5 Select the RX device signal source required to be spliced first according to the IP address displayed by OSD 6 Open the TX device list in the monitoring point area select the required TX device and long press the left mouse button to drag it into the splicing box 7 Open the RX device list in the monitoring point area select the required RX ...

Page 30: ...30 Operating Instruction ...

Page 31: ...indow TX device list window RX device list window and function selection window As shown below 1 select KVM in the function selection window 2 select the TX device to be configured in the TX list window 3 in the RX list window select the RX device to be configured click the left mouse button to select the device hold down the Ctrl key then select the device with the left mouse button for multiple ...

Page 32: ...32 IR RS232 Operating Instruction ...

Page 33: ...d indicated as below Parts 2 Year Labor 90 Days which starts with the date of original purchase Limited Warranty period at its option either a repair your product with new or refurbished parts or b replace it with a new of a refurbished product The decision to repair or replace will be made by the warrantor During the Labor Limited Warranty period there will be no charge for labor During the Parts...

Page 34: ...TY COVERAGE THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRNTY As examples this excludes damages for lost time cost of having someone remove or re install an installed unit if applicable travel to and from the service loss of or damage to media or images data or other recorded content The items lis...

Reviews: