LED Indicator

There are 3 LED in JetCon 2502 V2 and 2 LED RJ-45 Connector.

Mountthe unit

Screwed up the DIN-rail clip on the rear of 

JetCon 2502 V2 and mount on the 

EN50022 type rail. For more details, please 

refer to user’s manual.

JetCon 2502 V2

Quick Installation Guide v1.0

Copyright

Copyright © 2014 all rights reserved. No part ofthis publication may

be reproduced, adapted, stored in a retrieval system, translated into

any language, or transmitted in any form or by any means without

the written permission ofthe supplier.

Aboutthe Quick Installation Guide

This Quick Installation Guide is intended to guide professional

installer to install and configure the JetCon 2502 V2. It covers

procedures to assist you in avoiding unforeseen problems.

Installation

Introduction

DIP Switch Setting

Package Check List

JetCon 2502 V2 Industrial Media Converter

Quick Installation Guide

Power Adapetr (Optional)

5 Years Warranty

Each of Korenix’s product line is designed, produced, and tested with

high industrial standard. Korenix warrants thatthe Product(s) shall be

free from defects in materials and workmanship for a period offive (5)

years from the date of delivery provided thatthe Product was properly

installed and used.

This is warranty is voided if defects, malfunctions or failures ofthe

warranted Product are caused by damage resulting from force measure

(such as floods, fire, etc.), other external forces such as power

disturbances, over spec power input, or incorrect cabling; or the

warranted productis misused, a bused, or operated, altered and

repaired in an unauthorized or improper way.

Attention! To avoid system damage caused by sparks, please DO NOT

plug in power connector when power is on.

The productis in compliance with Directive 2002/95/EC and 2011/65/EU

ofthe European Parliament and ofthe Council of 27 January 2003 on the

restriction ofthe use of certain hazardous substances in electrical and

electronics equipment (RoHS Directives & RoHS 2.0)

Korenix Customer Service

KoreCARE is Korenix Technology's global service center, where our

professional staff are ready to solve your problems at any time Korenix

global service center's e-mail is [email protected].

For more information and documents download please visit our website:

http://www.korenix.com/downloads.htm

Support

JetCon 2502 V2 provides 4 DIP switches for 

system configuration; each DIP switch has 

independent function. Please refer to the 

following description.

DIP Switch -1: Mode selection.

Master mode (On): Acts as Central office (master).

Slave mode (Off): Acts as remote office (slave).

DIP Switch -2/3/4: Profile selection.

There are 8 different kinds of selection. Details listed as below.

Note:

Each JetCon 2502 V2 mode should correspond to central (master) or

 

remote (slave) installation. The default setting is slave mode (off)

JetCon 2502 V2 is an Ethernet/POTS to VDSL2 extender. It allows the 

VDSL2 carriers to deliver Ethernet data up to 100Mbps in both 

upstream and downstream over existing twisted copper. It is an ideal 

solution  to  carry  Ethernet  Data  stream  to  2500  meters  far  away  to 

extend local LAN and voice on the same line.

Wiring the Power Inputs

1. Insert the positive and negative wires into   

    the V+ and V- contacts respectively of the 

    terminal block connector.

2. Tighten the wire-clamp screws to prevent  

    loosened.

3. The terminal block input and DC jack input         

    supports power redundancy.

4. The Chassis Earth Ground must well connect with Earth Ground to 

provide good electrical magnetic immunity.

Note:

The recommended working voltage is DC 12V. 

(Input range: DC10~ 60 V)

Connecting the VDSL2 Network

1. Take out two JetCon 2502 V2 from the package box; one emulate 

    CO site (local), and the other one is CPE site (remote).

2. Apply the power into JetCon 2502 V2 and check the power LED 

    status to make sure JetCon 2502 is ready.

3. Set the mode selection dip switch 1 to “on” to enable master 

    function on JetCon 2502 in the local site; the  other JetCon 2502 V2 

    in the remote site should be off.

4. Connect PC to the 10/100Mbps RJ-45 connector of both JetCon 

    2502 V2 with standardized Ethernet cable.

5. Connect the VDSL2 ports of two JetCon 2502 V2 by one pair UTP 

    cable and check the VDSL LED status to make sure the VDSL 

    connection is ready. Please refer to below LED indicators.

6. Check the LED Ethernet port of both sites are ready. 

Note:

1. The cable length should under 800 meters to make 24/24 dB 

     effective.

2. For more profile config explanation, please refer user’s manual.

LED   

Status 

Description 

Fast Ethernet 

Speed (RJ-45) 

Yellow on 

Link on 100Mbps 

Off 

Link on 10Mbps or no link. 

Fast Ethernet 

Link/Activity 

(RJ-45) 

Green on 

The port is link on 10 or 100Mbps 

Blinking 

The port is on transmitting/receiving data. 

Off 

There is no device attached. 

VDSL 

Green Fast 

Blinking 

VDSL in handshake state 

Green Slow 

Blinking 

VDSL is active and in idle state 

Green On 

VDSL communication is ready 

Master 

Green on 

Ethernet/VDSL Extender is working on Master 

mode. 

Green off 

Ethernet/VDSL Extender is working on Slave mode.   

Power 

Green on 

The power is applied. 

Blinking 

No power. 

 

Profile # 

DIP Switch 

Profile Config 

Rate Limit 

DS/US 

(Mbps) 

  SNR   

DS/US 

(dBm) 

Master 

Profile 1 

OFF  OFF  OFF  OFF  M_Sy_Auto_G.inp 

160/160 

8/8 

Profile 2 

OFF  OFF  OFF  ON  M_NSy_Auto_G.inp 

220/110 

8/8 

Profile 3 

OFF  OFF  ON  OFF  M_Sy_Auto_I 

160/160 

6/6 

Profile 4 

OFF  OFF  ON  ON  M_NSy_Auto_I 

220/110 

6/6 

Profile 5 

OFF  ON  OFF  OFF  M_Sy_Auto_G.inp 

150/150 

12/12 

Profile 6 

OFF  ON  OFF  ON  M_NSy_Auto_G.inp 

200/100 

12/12 

Profile 7 

OFF  ON  ON  OFF  M_Sy_30a_G.inp 

20/20 

24/24 

Profile 8 

OFF  ON  ON  ON  A_17a-eu32_I 

150/50 

6/6 

Slave 

ON 

 