LED Indicator
There are 3 LED in JetCon 2502 V2 and 2 LED RJ-45 Connector.
Mountthe unit
Screwed up the DIN-rail clip on the rear of
JetCon 2502 V2 and mount on the
EN50022 type rail. For more details, please
refer to user’s manual.
JetCon 2502 V2
Quick Installation Guide v1.0
Copyright
Copyright © 2014 all rights reserved. No part ofthis publication may
be reproduced, adapted, stored in a retrieval system, translated into
any language, or transmitted in any form or by any means without
the written permission ofthe supplier.
Aboutthe Quick Installation Guide
This Quick Installation Guide is intended to guide professional
installer to install and configure the JetCon 2502 V2. It covers
procedures to assist you in avoiding unforeseen problems.
Installation
Introduction
DIP Switch Setting
Package Check List
JetCon 2502 V2 Industrial Media Converter
Quick Installation Guide
Power Adapetr (Optional)
5 Years Warranty
Each of Korenix’s product line is designed, produced, and tested with
high industrial standard. Korenix warrants thatthe Product(s) shall be
free from defects in materials and workmanship for a period offive (5)
years from the date of delivery provided thatthe Product was properly
installed and used.
This is warranty is voided if defects, malfunctions or failures ofthe
warranted Product are caused by damage resulting from force measure
(such as floods, fire, etc.), other external forces such as power
disturbances, over spec power input, or incorrect cabling; or the
warranted productis misused, a bused, or operated, altered and
repaired in an unauthorized or improper way.
Attention! To avoid system damage caused by sparks, please DO NOT
plug in power connector when power is on.
The productis in compliance with Directive 2002/95/EC and 2011/65/EU
ofthe European Parliament and ofthe Council of 27 January 2003 on the
restriction ofthe use of certain hazardous substances in electrical and
electronics equipment (RoHS Directives & RoHS 2.0)
Korenix Customer Service
KoreCARE is Korenix Technology's global service center, where our
professional staff are ready to solve your problems at any time Korenix
global service center's e-mail is [email protected].
For more information and documents download please visit our website:
http://www.korenix.com/downloads.htm
Support
JetCon 2502 V2 provides 4 DIP switches for
system configuration; each DIP switch has
independent function. Please refer to the
following description.
DIP Switch -1: Mode selection.
Master mode (On): Acts as Central office (master).
Slave mode (Off): Acts as remote office (slave).
DIP Switch -2/3/4: Profile selection.
There are 8 different kinds of selection. Details listed as below.
Note:
Each JetCon 2502 V2 mode should correspond to central (master) or
remote (slave) installation. The default setting is slave mode (off)
JetCon 2502 V2 is an Ethernet/POTS to VDSL2 extender. It allows the
VDSL2 carriers to deliver Ethernet data up to 100Mbps in both
upstream and downstream over existing twisted copper. It is an ideal
solution to carry Ethernet Data stream to 2500 meters far away to
extend local LAN and voice on the same line.
Wiring the Power Inputs
1. Insert the positive and negative wires into
the V+ and V- contacts respectively of the
terminal block connector.
2. Tighten the wire-clamp screws to prevent
loosened.
3. The terminal block input and DC jack input
supports power redundancy.
4. The Chassis Earth Ground must well connect with Earth Ground to
provide good electrical magnetic immunity.
Note:
The recommended working voltage is DC 12V.
(Input range: DC10~ 60 V)
Connecting the VDSL2 Network
1. Take out two JetCon 2502 V2 from the package box; one emulate
CO site (local), and the other one is CPE site (remote).
2. Apply the power into JetCon 2502 V2 and check the power LED
status to make sure JetCon 2502 is ready.
3. Set the mode selection dip switch 1 to “on” to enable master
function on JetCon 2502 in the local site; the other JetCon 2502 V2
in the remote site should be off.
4. Connect PC to the 10/100Mbps RJ-45 connector of both JetCon
2502 V2 with standardized Ethernet cable.
5. Connect the VDSL2 ports of two JetCon 2502 V2 by one pair UTP
cable and check the VDSL LED status to make sure the VDSL
connection is ready. Please refer to below LED indicators.
6. Check the LED Ethernet port of both sites are ready.
Note:
1. The cable length should under 800 meters to make 24/24 dB
effective.
2. For more profile config explanation, please refer user’s manual.
LED
Status
Description
Fast Ethernet
Speed (RJ-45)
Yellow on
Link on 100Mbps
Off
Link on 10Mbps or no link.
Fast Ethernet
Link/Activity
(RJ-45)
Green on
The port is link on 10 or 100Mbps
Blinking
The port is on transmitting/receiving data.
Off
There is no device attached.
VDSL
Green Fast
Blinking
VDSL in handshake state
Green Slow
Blinking
VDSL is active and in idle state
Green On
VDSL communication is ready
Master
Green on
Ethernet/VDSL Extender is working on Master
mode.
Green off
Ethernet/VDSL Extender is working on Slave mode.
Power
Green on
The power is applied.
Blinking
No power.
Profile #
DIP Switch
Profile Config
Rate Limit
DS/US
(Mbps)
SNR
DS/US
(dBm)
1
2
3
4
Master
Profile 1
OFF OFF OFF OFF M_Sy_Auto_G.inp
160/160
8/8
Profile 2
OFF OFF OFF ON M_NSy_Auto_G.inp
220/110
8/8
Profile 3
OFF OFF ON OFF M_Sy_Auto_I
160/160
6/6
Profile 4
OFF OFF ON ON M_NSy_Auto_I
220/110
6/6
Profile 5
OFF ON OFF OFF M_Sy_Auto_G.inp
150/150
12/12
Profile 6
OFF ON OFF ON M_NSy_Auto_G.inp
200/100
12/12
Profile 7
OFF ON ON OFF M_Sy_30a_G.inp
20/20
24/24
Profile 8
OFF ON ON ON A_17a-eu32_I
150/50
6/6
Slave
ON
-
-
-
-
-
-