background image

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material
or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state or country to country.

OUR EQUIPMENT*

OUTBOARD

MOTOR

PRESSURE

WASHER

WATER PUMP

(Not available in the

USA)

PORTABLE

GENERATOR

WELDER

L

Le

es

ss

s  tth

ha

an

n  1

10

0  K

KW

W

1

10

0  K

KW

W  o

orr  g

grre

ea

atte

err

T

Trra

an

ns

sffe

err  s

sw

wiittc

ch

h

2 years

none

1 year

90 days

1 year

90 days

2 years

1 year

2 years

none

3 years or

1500 hours

none

3 years

none

WARRANTY PERIOD**

HOME STANDBY GENERATOR SYSTEM

Consumer Use

Commercial Use

*

The engine and starting batteries are warranted solely by the manufacturers of those products.

**

2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and
Home Standby Generator System - Less than 10 KW, outside of European Union.

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter
be considered as commercial use for purposes of this warranty.

Equipment used for prime power in place of utility are not applicable to

this warranty. Electric powered pressure washers used for commercial purposes are not warranted.

NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not
apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.
Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered
or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to
be defective under normal use and service. This warranty will not cover the following repairs and equipment:

Normal Wear:

Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not

cover repair when normal use has exhausted the life of a part or the equipment.

Installation and Maintenance:

This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized

installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as,
in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments,
fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).

Other Exclusions:

This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that

have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing
or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. This
warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control. Also excluded is used,
reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life support
applications. 

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WI, USA

Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004

Summary of Contents for Elite 030209-1

Page 1: ...M F 8 5 CT Llamada Generador Helpline 1 800 743 4115 M F 8 5 CT web www briggsandstratton com 030209 1 5500W BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Before using this produc...

Page 2: ...formation refer to the Engine Operator s Manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symb...

Page 3: ...arette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates before start...

Page 4: ...ore stopping generator Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnec...

Page 5: ...l number of generator Please have these readily available when calling for assistance Fuel Tank Capacity of seven 7 U S gallons Grounding Fastener Consult your local agency having jurisdiction for gro...

Page 6: ...ntents against those listed below Main unit Engine oil Operator s manual Engine operator s manual Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 Install Wh...

Page 7: ...NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of...

Page 8: ...as to collect in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator When using generator for backup power notify utility company U...

Page 9: ...or and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stoppi...

Page 10: ...ds requiring up to 5 500 watts of power 5 5 kW at 22 9 Amps for 240 Volts or two independent 120 Volt loads at 20 Amps each The outlet is protected by push to reset circuit breakers 120 Volt AC 20 Amp...

Page 11: ...r output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additiona...

Page 12: ...ater can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator wind...

Page 13: ...rom forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carbureto...

Page 14: ...no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Gener...

Page 15: ...ctric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT I...

Page 16: ...n Ambiental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el Manual del Operario de Motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de...

Page 17: ...a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible espere a que se evapore antes de a...

Page 18: ...ador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conectados al mismo PRECAUCI N CUANDO AJUSTE O HAGA R...

Page 19: ...a posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Tapa del Dep sito del Aceite Llene el motor con aceite aqu Tanque...

Page 20: ...l cart n para instalar el juego de ruedas Contenido de la Caja Revise todo el contenido compar ndolo con la lista a continuaci n Unidad Principal Aceite del Motor Manual del Operario Manual del Operar...

Page 21: ...5 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 3 Agregue lentamente combustible r...

Page 22: ...n del generador Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica...

Page 23: ...las cargas el ctricas y descon ctelas del generador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conect...

Page 24: ...a 22 9 Amperios para 120 Voltios 5 500 vatios de energ a 5 5 kW a 22 9 Amperios para 240 Voltios La salida est protegida por un corto circuito de del tipo empuje para reposicionar 120 Volt AC 20 Amp...

Page 25: ...suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adici...

Page 26: ...angueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras p...

Page 27: ...xidarse El xido y o la suciedad en la gasolina le causar problemas Almacene la unidad en un rea limpia y seca DIAGNOSITICOS DE AVER AS Problemo Accion Causa El motor est funcionando pero no existe sal...

Page 28: ...VICIO DE BRIGGS STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT...

Reviews: