background image

7

5500W Portable Generator

6.

Repeat step 3 thru 5 to secure second wheel.

7.

Tip generator so that engine side is down.

8.

Attach support leg using two 1/2” or 13mm wrenches
with 20mm cap screws and lock nuts.

9.

Center lifting handle on cradle. Attach handle using
two 1/2” or 13mm wrenches with 45mm capscrews
and hex nuts.

10. Return generator to normal operating position (resting

on wheels and support leg).

11. Check each fastener to ensure it is secure.

BEFORE STARTING THE

ENGINE

Add Engine Oil

• Place generator on a level surface.

• Refer to engine operator’s manual and follow oil

recommendations and instructions.

NOTE: Check oil often during engine break–in. Refer to
engine operator’s manual for recommendations.

NOTE: The generator assembly rotates on a prelubricated
and sealed ball bearing that requires no additional
lubrication for the life of the bearing.

Add Fuel

NOTE: This gasoline engine is certified to operate on
gasoline. Exhaust Emission Control System: EM (Engine
Modifications).

1.

Use clean, fresh, regular UNLEADED fuel with a
minimum of 85 octane. DO NOT use fuel which
contains Methanol. DO NOT mix oil with fuel.

2.

Clean area around fuel fill cap, remove cap.

3.

Slowly add regular unleaded fuel to fuel tank. Be careful
not to overfill. Allow about 1.5" of tank space for fuel
expansion (Figure 2).

4.

Install fuel cap and wipe up any spilled fuel.

CAUTION

• Refer to engine operator’s manual for oil fill information.

• Damage to equipment resulting from failure to follow this

instruction will void warranty.

Any attempt to crank or start the engine before it has
been properly filled with the recommended oil will result
in equipment failure.

WHEN ADDING FUEL
• Turn generator OFF and let it cool at least 2 minutes before

removing fuel cap. Loosen cap slowly to relieve pressure in
tank.

• Fill fuel tank outdoors.

• DO NOT overfill tank. Allow space for fuel expansion.

• Keep fuel away from sparks, open flames, pilot lights, heat, and

other ignition sources.

• DO NOT light a cigarette or smoke.

Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.

WARNING

Fuel

Tank

1.5” Air 

Space

Figure 2 - Fuel Expansion

• Always wear eye protection when installing/removing e-rings.

E-rings can cause eye injury.
E-rings can spring back and become airborne
when installing or removing.

CAUTION

Summary of Contents for Elite 030209-1

Page 1: ...M F 8 5 CT Llamada Generador Helpline 1 800 743 4115 M F 8 5 CT web www briggsandstratton com 030209 1 5500W BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Before using this produc...

Page 2: ...formation refer to the Engine Operator s Manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symb...

Page 3: ...arette or smoke WHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates before start...

Page 4: ...ore stopping generator Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnec...

Page 5: ...l number of generator Please have these readily available when calling for assistance Fuel Tank Capacity of seven 7 U S gallons Grounding Fastener Consult your local agency having jurisdiction for gro...

Page 6: ...ntents against those listed below Main unit Engine oil Operator s manual Engine operator s manual Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 Install Wh...

Page 7: ...NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of...

Page 8: ...as to collect in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator When using generator for backup power notify utility company U...

Page 9: ...or and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stoppi...

Page 10: ...ds requiring up to 5 500 watts of power 5 5 kW at 22 9 Amps for 240 Volts or two independent 120 Volt loads at 20 Amps each The outlet is protected by push to reset circuit breakers 120 Volt AC 20 Amp...

Page 11: ...r output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additiona...

Page 12: ...ater can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator wind...

Page 13: ...rom forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carbureto...

Page 14: ...no load but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Gener...

Page 15: ...ctric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT I...

Page 16: ...n Ambiental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el Manual del Operario de Motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta de...

Page 17: ...a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible espere a que se evapore antes de a...

Page 18: ...ador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conectados al mismo PRECAUCI N CUANDO AJUSTE O HAGA R...

Page 19: ...a posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Tapa del Dep sito del Aceite Llene el motor con aceite aqu Tanque...

Page 20: ...l cart n para instalar el juego de ruedas Contenido de la Caja Revise todo el contenido compar ndolo con la lista a continuaci n Unidad Principal Aceite del Motor Manual del Operario Manual del Operar...

Page 21: ...5 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie el rea alrededor de la tapa de llenado del combustible retire la tapa 3 Agregue lentamente combustible r...

Page 22: ...n del generador Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica...

Page 23: ...las cargas el ctricas y descon ctelas del generador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conect...

Page 24: ...a 22 9 Amperios para 120 Voltios 5 500 vatios de energ a 5 5 kW a 22 9 Amperios para 240 Voltios La salida est protegida por un corto circuito de del tipo empuje para reposicionar 120 Volt AC 20 Amp...

Page 25: ...suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adici...

Page 26: ...angueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras p...

Page 27: ...xidarse El xido y o la suciedad en la gasolina le causar problemas Almacene la unidad en un rea limpia y seca DIAGNOSITICOS DE AVER AS Problemo Accion Causa El motor est funcionando pero no existe sal...

Page 28: ...VICIO DE BRIGGS STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT...

Reviews: