background image

Not for 

Reproduction

BRIGGSandSTRATTON.com.au

Equipment Description
Table of Contents

Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . 2
Features and Controls  . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting/Specifications . . . . . . . . . . . . . . . . . 15
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Symbols and Meanings

Signal

Meaning

DANGER

Indicates a hazard which, if not avoided, 

will

 

result in death or serious injury.

WARNING

Indicates a hazard which, if not avoided, 

could

 

result in death or serious injury.

CAUTION

Indicates a hazard which, if not avoided, 

could

 

result in minor or moderate injury.

NOTICE

Indicates information considered important, but 

not hazard-related.

Symbol Name

Explanation

Safety Alert 

Symbol

Indicates a potential personal injury 

hazard.

Operator’s 

Manual

Failure to follow warnings, 

instructions and operator’s manual 

could result in death or serious 

injury.

Toxic Fumes

Engine exhaust contains carbon 

monoxide, a poisonous gas that 

could kill you in minutes.  You 

cannot smell it or see it. 

Fire

Fuel and its vapors are extremely 

flammable which could cause 

burns or fire resulting in death or 

serious injury.

Engine exhaust could cause fire 

resulting in death or serious injury.  

Electric 

Shock

Generator could cause electrical 

shock resulting in death or serious 

injury.

Hot Surface

Muffler could cause burns or 

resulting in serious injury.

Equipment Description

  

Read this manual carefully and become familiar 

with your outdoor generator. Know its applications, 

its limitations, and any hazards involved. Save 

these original instructions for future reference.

The outdoor generator is an engine–driven, revolving 

field, alternating and direct current (AC & DC) generator. 

It was designed to supply electrical power for operating 

compatible electrical lighting, appliances, tools and motor 

loads. The generator’s revolving field is driven by a single-

cylinder engine.
The portable generator can be used to power outdoor 

items using an extension cord or to restore home power 

using a transfer switch. A transfer switch is a separate 

device installed by a licensed electrician that allows 

the portable generator to be cord connected, using the 

receptacle, directly into your home’s electrical system. 

Install a manual transfer switch as soon as possible if 

generator will be used to provide home power restoration.
The generator is not intended to supply systems that are 

legally required, for serious life safety or health hazards, 

or where lack of power hampers rescue of fire-fighting 

operations.
Every effort has been made to ensure that the information 

in this manual is both accurate and current. However, 

the manufacturer reserves the right to change, alter or 

otherwise improve the generator and this documentation at 

any time without prior notice.

NOTICE   

If you have questions about intended use,  

contact an authorized service dealer. This equipment is 

designed to be used with Briggs & Stratton® authorized 

parts only.

System Ground

The generator has a system ground that connects the 

generator frame components to the ground terminals on 

the AC output receptacles. The generator neutral is floating, 

which means that the AC stator winding is isolated from 

the grounding fastener and the AC receptacle ground pins. 

Electrical devices, such as RCD, requiring a grounded 

neutral may not operate properly from this generator. 

Earthing of the generator is not required.

Special Requirements

There may be regulations, local codes, or ordinances that 

apply to the intended use of the generator. Please consult 

a qualified electrician, electrical inspector, or the local 

agency having jurisdiction.
This generator is not intended to be used at a construction 

site.

www.caravansplus.com.au

Summary of Contents for 030802

Page 1: ...___________________________ Revision __________________________________ Serial Number ______________________________ Date Purchased ____________________________ Copyright 2020 Briggs Stratton Corporat...

Page 2: ...ng appliances tools and motor loads The generator s revolving field is driven by a single cylinder engine The portable generator can be used to power outdoor items using an extension cord or to restor...

Page 3: ...and off Recoil Starter Used to start the engine manually Retractable Handle Press button and pull handle out to move generator Press button to push handle back in Side Maintenance Cover Remove to gai...

Page 4: ...utdown system fault occurred Circuit Breaker A push to reset circuit breaker is provided to protect the generator against electrical overload DC Circuit Breaker The 12 Volt DC receptacle is provided w...

Page 5: ...N o t f o r R e p r o d u c t i o n 5 Exhaust muffler Point away from home Features and Controls www caravansplus com au...

Page 6: ...posed to carbon monoxide gas Operate portable generator only outdoors at least 6 1 m 20 ft from occupied spaces with exhaust pointed away to reduce the risk of carbon monoxide accumulating Install bat...

Page 7: ...ntenance cover screws Low Oil Indicator The low oil indicator system is designed to prevent engine damage caused by not enough engine oil If the engine oil level drops below a preset level the yellow...

Page 8: ...andle twice If engine fails to start repeat steps 3 thru 4 6 Slowly move choke lever to RUN position If engine falters move choke lever to half choke position until engine runs smoothly and then to RU...

Page 9: ...perating normally It indicates that the generator is producing power at the receptacles Overload Alarm The red LED overload alarm light comes on and cuts power to the receptacles if you overload the g...

Page 10: ...atts for the items you will power at the same time follow these three simple steps 1 Select the items you will power at the same time See following list for typical wattages Typical wattages listed ar...

Page 11: ...panel receptacles Never stop engine with electrical devices plugged in and turned on 2 Let engine run at no load for one minute to stabilize internal temperatures of engine and generator 3 Turn engin...

Page 12: ...he two maintenance cover screws and remove the side maintenance cover 3 Clean area around oil fill remove oil fill cap and check oil level 4 If needed slowly pour oil into oil fill opening to the poin...

Page 13: ...oth 6 SATURATE foam air cleaner in clean engine oil and squeeze in a clean cloth to remove excess oil 7 Reinstall clean or new foam air cleaner inside base 8 Reinstall clean or new breather filter ins...

Page 14: ...ainer with fuel add STA BIL 360 PROTECTION to the fuel as specified by the manufacturer s instructions This keeps fuel fresh and decreases fuel related problems or contamination in the fuel system It...

Page 15: ...kcase to proper level or place generator on level surface 3 Clean or replace air cleaner 4 Fill fuel tank 5 Connect wire to spark plug 6 Wait 5 minutes and re crank engine Engine shuts down and CO shu...

Page 16: ...use In Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any...

Reviews: