Not for
Reproduction
11
Maintenance
Power Management
To manage generator power, sequentially add loads as
follows:
1. With nothing connected to generator, start the engine
outdoors.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider starting watts in generator capacity.
Carbon Monoxide (CO) Shutdown System
Automatically shuts down the engine when harmful levels
of carbon monoxide accumulate around the generator or
a CO shutdown system fault occurs. After shutdown, the
indicator light will blink for at least five minutes per the
chart below.
The CO shutdown system DOES NOT replace carbon
monoxide alarms. Install battery-powered carbon monoxide
alarm(s) in your home. Do not run generator in enclosed
areas.
Color/Pattern
Description
Red
•• ••
Carbon monoxide accumulated around
generator. Move generator to an
open, outdoor area 6.1 m (20 ft.) from
occupied spaces with exhaust pointed
away. Automatic shutoff is an indication
generator was improperly located. Air
out premises (e.g. open windows and
doors) before reoccupying.
If you start to feel sick, dizzy, weak, or
your homes carbon monoxide alarm
sounds while using this product, get
to fresh air right away. Call emergency
services. You may have carbon
monoxide poisoning.
Blue
• • •
CO shutdown system fault occured*.
See Briggs & Stratton authorized service
dealer.
*Blue light will blink for five seconds at the startup of generator to
show the CO shutdown system is functioning properly.
Step 5: Generator Shutdown
1. Turn off and unplug all electrical loads from generator
panel receptacles. Never stop engine with electrical
devices plugged in and turned on.
2. Let engine run at no-load for one minute to stabilize
internal temperatures of engine and generator.
3. Turn engine switch to the off position.
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in
adverse conditions noted below.
1
Service more often under dirty or dusty conditions.
2
See any authorized dealer for service.
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any Briggs & Stratton
Authorized Service Dealer for maintenance and service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To receive
full value from the warranty, the operator must maintain the
generator as instructed in this manual.
All service and adjustments should be made at least once
each season. A new spark plug and clean air filter assure
proper fuel-air mixture and help your engine run better and
last longer. Follow requirements in
Maintenance Schedule
.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual.
However, to obtain ”no charge” emissions control service,
the work must be performed by a factory authorized dealer.
See
Emissions Warranty
.
The emissions control system for carbureted engines is
EM (Engine Modifications). The emissions control systems
for engines with electronic fuel injection are ECM (Engine
Control Module), MPI (Multi Port Injection), and if equipped
an O2S (Oxygen Sensor).
• Generator is equipped with a G-trim engine.
Every 8 Hours or Daily
• Clean debris
• Check engine oil level
First Month or 10 Hours
• Change engine oil
Every 50 Hours or 3 Months
• Clean engine air cleaner
1
Every 100 Hours or 6 Months
• Change engine oil
1
• Service spark plug
• Inspect muffler and spark arrester
1, 2
• Clean fuel sediment cup
2
www.caravansplus.com.au