Maintenance

Power Management

To manage generator power, sequentially add loads as 

follows:
  1.  With nothing connected to generator, start the engine 

outdoors.

  2.  Plug in and turn on the first load, preferably the largest 

load you have.

  3.  Permit the generator output to stabilize (engine runs 

smoothly and attached device operates properly).

  4.  Plug in and turn on the next load.
  5.  Again, permit the generator to stabilize.
  6.  Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take 

special care to consider starting watts in generator capacity.

Carbon Monoxide (CO) Shutdown System

Automatically shuts down the engine when harmful levels 

of carbon monoxide accumulate around the generator or 

a CO shutdown system fault occurs. After shutdown, the 

indicator light will blink for at least five minutes per the 

chart below.
The CO shutdown system DOES NOT replace carbon 

monoxide alarms. Install battery-powered carbon monoxide 

alarm(s) in your home. Do not run generator in enclosed 

areas. 

Color/Pattern

Description

Red

••  •• 

Carbon monoxide accumulated around 

generator. Move generator to an 

open, outdoor area 6.1 m (20 ft.) from 

occupied spaces with exhaust pointed 

away. Automatic shutoff is an indication 

generator was improperly located. Air 

out premises (e.g. open windows and 

doors) before reoccupying.
If you start to feel sick, dizzy, weak, or 

your homes carbon monoxide alarm 

sounds while using this product, get 

to fresh air right away. Call emergency 

services. You may have carbon 

monoxide poisoning.

Blue

•  •  •

CO shutdown system fault occured*. 

See Briggs & Stratton authorized service 

dealer.

*Blue light will blink for five seconds at the startup of generator to 

show the CO shutdown system is functioning properly.

Step 5: Generator Shutdown

  1.  Turn off and unplug all electrical loads from generator 

panel receptacles. Never stop engine with electrical 

devices plugged in and turned on.

  2.  Let engine run at no-load for one minute to stabilize 

internal temperatures of engine and generator.

  3.  Turn engine switch to the off position.

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs 

first. More frequent service is required when operating in 

adverse conditions noted below.

 

1

 

Service more often under dirty or dusty conditions.

 

2

 

See any authorized dealer for service.

 

General Recommendations

Regular maintenance will improve the performance and 

extend the life of the generator. See any Briggs & Stratton 

Authorized Service Dealer for maintenance and service.
The generator’s warranty does not cover items that have 

been subjected to operator abuse or negligence. To receive 

full value from the warranty, the operator must maintain the 

generator as instructed in this manual.
All service and adjustments should be made at least once 

each season. A new spark plug and clean air filter assure 

proper fuel-air mixture and help your engine run better and 

last longer. Follow requirements in 

Maintenance Schedule

.

Emissions Control

Maintenance, replacement, or repair of the emissions 

control devices and systems may be performed by any 

non-road engine repair establishment or individual. 

However, to obtain ”no charge” emissions control service, 

the work must be performed by a factory authorized dealer. 

See 

Emissions Warranty

The emissions control system for carbureted engines is 

EM (Engine Modifications). The emissions control systems 

for engines with electronic fuel injection are ECM (Engine 

Control Module), MPI (Multi Port Injection), and if equipped 

an O2S (Oxygen Sensor).
  •  Generator is equipped with a G-trim engine.

Every 8 Hours or Daily

  •  Clean debris
  •  Check engine oil level

First Month or 10 Hours

  •  Change engine oil

Every 50 Hours or 3 Months

  •  Clean engine air cleaner

1

Every 100 Hours or 6 Months

  •  Change engine oil

1

  •  Service spark plug
  •  Inspect muffler and spark arrester

1, 2

  •  Clean fuel sediment cup

2

www.caravansplus.com.au

Summary of Contents for 030802

Page 1: ...___________________________ Revision __________________________________ Serial Number ______________________________ Date Purchased ____________________________ Copyright 2020 Briggs Stratton Corporat...

Page 2: ...ng appliances tools and motor loads The generator s revolving field is driven by a single cylinder engine The portable generator can be used to power outdoor items using an extension cord or to restor...

Page 3: ...and off Recoil Starter Used to start the engine manually Retractable Handle Press button and pull handle out to move generator Press button to push handle back in Side Maintenance Cover Remove to gai...

Page 4: ...utdown system fault occurred Circuit Breaker A push to reset circuit breaker is provided to protect the generator against electrical overload DC Circuit Breaker The 12 Volt DC receptacle is provided w...

Page 5: ...N o t f o r R e p r o d u c t i o n 5 Exhaust muffler Point away from home Features and Controls www caravansplus com au...

Page 6: ...posed to carbon monoxide gas Operate portable generator only outdoors at least 6 1 m 20 ft from occupied spaces with exhaust pointed away to reduce the risk of carbon monoxide accumulating Install bat...

Page 7: ...ntenance cover screws Low Oil Indicator The low oil indicator system is designed to prevent engine damage caused by not enough engine oil If the engine oil level drops below a preset level the yellow...

Page 8: ...andle twice If engine fails to start repeat steps 3 thru 4 6 Slowly move choke lever to RUN position If engine falters move choke lever to half choke position until engine runs smoothly and then to RU...

Page 9: ...perating normally It indicates that the generator is producing power at the receptacles Overload Alarm The red LED overload alarm light comes on and cuts power to the receptacles if you overload the g...

Page 10: ...atts for the items you will power at the same time follow these three simple steps 1 Select the items you will power at the same time See following list for typical wattages Typical wattages listed ar...

Page 11: ...panel receptacles Never stop engine with electrical devices plugged in and turned on 2 Let engine run at no load for one minute to stabilize internal temperatures of engine and generator 3 Turn engin...

Page 12: ...he two maintenance cover screws and remove the side maintenance cover 3 Clean area around oil fill remove oil fill cap and check oil level 4 If needed slowly pour oil into oil fill opening to the poin...

Page 13: ...oth 6 SATURATE foam air cleaner in clean engine oil and squeeze in a clean cloth to remove excess oil 7 Reinstall clean or new foam air cleaner inside base 8 Reinstall clean or new breather filter ins...

Page 14: ...ainer with fuel add STA BIL 360 PROTECTION to the fuel as specified by the manufacturer s instructions This keeps fuel fresh and decreases fuel related problems or contamination in the fuel system It...

Page 15: ...kcase to proper level or place generator on level surface 3 Clean or replace air cleaner 4 Fill fuel tank 5 Connect wire to spark plug 6 Wait 5 minutes and re crank engine Engine shuts down and CO shu...

Page 16: ...use In Australia Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any...

Reviews: