35-DVRS31NB(N)-2
37
With the system in “OFF” position press the Mode Key to index to the CPI mode icon.
Pressing the UP Arrow Key will activate the Continuous Pilot Ignition mode (CPI). Pressing the Down Arrow Key will return to IPI. A single
“beep” will confirm the reception of the command.
Continuous Pilot on Demand / Intermittent Pilot (CPI/IPI) Selection
REMOTE CONTROL SETUP AND OPERATION
AUTOMATIC SAFETY SHUT-OFF
This system will execute an automatic turn OFF command after a 24hr continuous main burner flame ignition. This allows
the system to verify correct safety functions.
DIAGNOSTIC INDICATIONS INFORMATION
Pilot Flame Error Condition:
- Red LED Indicator will commence a (2) blink sequence. Contact your dealer if this occurs.
System Lock Out Condition:
- Red LED Indicator will commence a (3) blink sequence. Make sure your gas is turned on.
- Make sure pilot sensor is not shorted out.
- Follow reset information above if the module goes into a Lock Out state.
LOW BATTERY CONDITION (Less than 4V):
Remote Control
- Battery Icon will appear on LCD remote control display. Replace batteries.
Battery Back-up
- Red LED indicator will enter a (1) blink sequence. IFC Module will emit a double-beep when it
receives an ON/OFF command from the hand held remote. Replace batteries.
Fig. 34
-
A
Fig. 34
-
B
CPI vs IPI:
Continuous Pilot on Demand Ignition (CPI)
: In this mode the pilot runs continuously even when the main burner is off. The Continu-
ous Pilot on Demand Ignition operates on a seven day cycle. If the main burner is not turned on for seven continuous days, the pilot will
turn itself off. When the main burner is lit again the cycle repeats. The pilot will remain lit for seven days, even after the main burner is
turned off. If the main burner is lit during a seven day timing cycle, the seven day timer will reset.
Intermittent Pilot Ignition (IPI)
: A fuel saving mode in which the pilot is only used when the main burner is on.
This appliance is shipped in IPI mode. IPI mode is often the preferred method, however, there are some situations where it may be pref-
erable to switch the fireplace into CPI mode. For example, in colder climates the glass door or the front of the fireplace could become
very cold to the touch. Dynamic Start Advantage will solve most problems experienced by older IPI operated fireplaces.