Installation Instructions Cont.
Horizontal Installation
The horizontal run must have a 1/4” rise per foot and must meet
all local and national building codes, and must not be easily
blocked or obstructed. Termination clearances are as follows:
A. Clearance above ground, verandah, porch, deck, or bal-
cony: 12” minimum (30 cm.)
B. Clearance to a window or door that may be opened: 9”
minimum (23 cm)
C. Vertical clearance to a ventilated soffit located above the
termination within a horizontal distance of 2 feet from the
centerline of the termination: 18” minimum (46 cm).
Note:
Clearances are to be in accordance with local installa-
tion codes and the requirements of the gas supplier.
D. Clearance to an unventilated soffit: 12” minimum (30 cm).
Note: Clearances are to be in accordance with local
installation codes and the requirements of the gas
supplier.
E. Clearance to an outside corner: 9” (23 cm).
Note: Clear-
ances are to be in accordance with local installation
codes and the requirements of the gas supplier.
F. Clearance to an inside corner: 9” (23 cm).
Note: Clear-
ances are to be in accordance with local installation
codes and the requirements of the gas supplier.
G. Do not install above a meter/regulator assembly within 3
feet (90 cm) horizontally from the centerline of the meter/
regulator.
Note: Clearances are to be in accordance
with local installation codes and the requirements of
the gas supplier.
H. Clearance to a service regulator vent outlet: 6’ minimum
(1.8 m)
I.
Clearance to a non-mechanical air supply inlet to a building
or the combustion air inlet to any other appliance: 12” mini-
mum (30 cm)
J.
Clearance to a mechanical air supply inlet: 6’ minimum (1.8
m)
K. Clearance above paved sidewalk or paved driveway lo-
cated on public property: refer to local code
L.
Clearance under open verandah, porch, deck, or balcony:
12” minimum (30 cm).
Note: Clearances are to be in ac-
cordance with local installation codes and the require-
ments of the gas supplier.
M. Maximum horizontal run 5’ after 2’ vertical rise. Liquid Pro-
pane gas 5’ horizontal run to 35’ vertical rise. Natural Gas
maximum 35’ horizontal run with 7’ vertical rise.
Note:
Clearances are to be in accordance with local installa-
tion codes and the requirements of the gas supplier.
Figure 22
–
Vent Termination Locations
Summary of Contents for 240DVRS25N
Page 8: ...24 DVRS25N 8 APPLIANCE DIMENSIONS Surround Installed Surround Removed...
Page 24: ...24 DVRS25N 24 LIGHTING INSTRUCTIONS ON RATING PLATE...
Page 26: ...24 DVRS25N 26 REMOTE CONTROL SETUP AND OPERATION...
Page 27: ...24 DVRS25N 27 REMOTE CONTROL SETUP AND OPERATION cont...
Page 28: ...24 DVRS25N 28 REMOTE CONTROL SETUP AND OPERATION cont...
Page 30: ...24 DVRS25N 30 REMOTE CONTROL SETUP AND OPERATION cont...
Page 32: ...24 DVRS25N 32 REMOTE CONTROL SETUP AND OPERATION cont...
Page 35: ...24 DVRS25N 35 CONVERSION KIT INSTRUCTIONS CONT VALVE CONVERSION...
Page 40: ...24 DVRS25N 40 NOTES...
Page 43: ...ARCHGARD FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...