background image

24-DVRS25NB(N)-2

 

25 

INITIAL OPERATION

 

1.

 

Check that the appliance is properly vented and connected to the gas supply.

 

2.

 

Check that all external parts, such as door and faceplate are properly attached and 

fastened.

 

3.

 

Do not operate this appliance with broken, cracked glass doors or without the door (s) in its 

correct (and latched) position. Do not abuse the glass by either striking or slamming shut.

 

4.

 

Check that there are no fingerprints left on glass panels, as high temperature can bake 

these prints on permanently.

 

FINAL INSTALLATION CHECK

 

Each Brigantia Gas Fireplace is checked and tested at the factory prior to being packaged and 

shipped to our dealers and finally installed in your home. Brigantia recommends that before 

leaving this unit with the customer, the installer must ensure that the appliance is firing 

 

correctly and that the electrical system is in working order. 

This will include:

 

 

1.

 

Perform leak tests of supply line, gas control valve, supply line from gas control valve and 

pilot assembly.

 

2.

 

Clocking the appliance to ensure the correct firing rate (see page 19 of this manual).

 

3.

 

If required, adjusting the primary air to burner to ensure that the flame does not carbon or 

soot.           

 

4.

 

Check for proper operation including correct drafting.

 

 

 

As a reminder, a TAG is attached to all of our gas fireplaces. This TAG is located at the gas 

control valve. See Fig 1.

 

Any alteration to the product that causes carboning or sooting that results in any 

 

damage or requires cleaning is not the responsibility of the manufacturer. 

 

ARCHGARD INDUSTRIES LTD.

 

 

*** INSTALLER ***

 

IMPORTANT NOTICE

 

 

ALL GAS AND ELECTRICAL CONNECTIONS 

 

** MUST ** BE CHECKED AND TESTED AT 

TIME OF INSTALLATION.

 

Fig 1.

 

Summary of Contents for 24-DVRS25NB-2

Page 1: ...ions If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be instal...

Page 2: ...gas pressures Adjusting Pilot and Convertible Pilot Orifice 20 Contemporary Panels 21 Component Removal Door Removal Surround Clip Installation 22 Safety Barrier Installation 23 Final Installation Ch...

Page 3: ...e fireplace could become very cold to the touch Dynamic Start Advantage will solve most problems experienced by older IPI operated fireplaces Please complete and submit the warranty registration card...

Page 4: ...24 DVRS25NB N 2 4 RATING PLATE...

Page 5: ...run Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical YES IF NO WHY NOT Connected to household 110 12...

Page 6: ...and liquids near the appliance Clothing or other flammable material should not be placed on or near the appliance WARNING Do not operate appliance with the glass front removed cracked or broken Remova...

Page 7: ...ectrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 We recommend that our gas hearth products be installed and serviced by professionals who are c...

Page 8: ...24 DVRS25NB N 2 8 APPLIANCE DIMENSIONS Surround Installed Surround Removed...

Page 9: ...1 2 wide x 39 1 2 high X 5 1 2 deep The bottom of the frame must be min 4 up from combustible floor Installation Instructions When installing on an exterior wall you must include the exterior wall in...

Page 10: ...drafts See figure 4 Figure 4 Install the nailing flanges provide by screwing them to the side of the outer shell using the hole required for the facing material Then place the fireplace into the frame...

Page 11: ...he 120V circuit must be electrically grounded in accordance with the local codes or in absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 E...

Page 12: ...om the edge of door unless otherwise noted Clearance to Combustibles Clearance to combustible floor must maintain clearances from the top surface of carpet flooring etc Nailing Flanges Install the nai...

Page 13: ...y spaced around the pipe These indentations are designed to slide over the male section of the pipe and fully lock by a clockwise quarter turn Vent Restrictors Due to the extra flow produced by tall v...

Page 14: ...standoff and the terminal Attach the terminal to the exterior wall using four wood screws through the holes in the corner of the vent terminal Complete the terminal installation and apply a bead of m...

Page 15: ...iling joists roof rafters or other framing will obstruct the vent system You may have to use 45 elbows to navigate around any obstacles When passing through a flat ceiling install a Box Wall thimble C...

Page 16: ...ide corner 9 23 cm Note Clear ances are to be in accordance with local installation codes and the requirements of the gas supplier G Do not install above a meter regulator assembly within 3 feet 90 cm...

Page 17: ...izontal Use restrictor setting No 1 Example C 17ft vertical rise 1 90 elbow 5ft horizontal Use restrictor setting No 2 Maximum horizontal elbows allowed 3 Note if more than 1 90 elbow is used hori zon...

Page 18: ...ct a switch if needed Separate wires to disable CPI activation from remote The SIT Control Module is powered by 120V with an internal transformer for the valve This is pre wired to the factory install...

Page 19: ...ndividual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas val...

Page 20: ...rify that the readings obtained are within specs as shown on the appliance rating plate 6 Be sure to tighten the set screw inside the tap after you have finished taking pressure readings 7 Check for l...

Page 21: ...Caution Handle contemporary Panels with care 1 Place side panels 2 and 3 in the firebox with notches facing forward as shown above 2 Place rear panel 1 into the back of the firebox 3 Insert the top a...

Page 22: ...top and two on the bottom Surround clip receivers will push on to these buttons Release the latch located on the bottom of door Pull forward and down Remove the door by pulling the bottom out to 30 d...

Page 23: ...houette Log Set Installation Optional Your Brigantia Fireplace is approved for use with the Optional Silhouette Log Set The logs come in White Black and Grey Each set comes with 2 logs and you can ins...

Page 24: ...24 DVRS25NB N 2 24...

Page 25: ...his unit with the customer the installer must ensure that the appliance is firing correctly and that the electrical system is in working order This will include 1 Perform leak tests of supply line gas...

Page 26: ...24 DVRS25NB N 2 26 LIGHTING INSTRUCTIONS ON RATING PLATE...

Page 27: ...replace you build a fire You start with a little bit of tinder and kindling to create small fire and then work your way up to larger logs once a draft has been established Dynamic Start uses the same...

Page 28: ...ront cover of this manual 3 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control s...

Page 29: ...ce of Continuous Pilot on Demand or intermittent pilot CPI IPI 4 Thermostat and SMART thermostat function 5 Comfort fan speed modulation 6 levels 6 Variable lights 6 levels The Proflame Remote uses a...

Page 30: ...INSTALLATION OR MAINTENANCE OF THE RECEIVER DEVICE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN CASE OF REMOTE CONTROL MALFUNCTION TURN OFF THE FIREPLACE...

Page 31: ...24 DVRS25NB N 2 31 REMOTE CONTROL SETUP AND OPERATION cont...

Page 32: ...place is started in Smart Thermostat mode the fan will come on 5min after ignition and shut down 12min after fire is turned off This function is disabled when in SMART Thermostat Mode and does not ope...

Page 33: ...24 DVRS25NB N 2 33 REMOTE CONTROL SETUP AND OPERATION cont...

Page 34: ...n burner is not turned on for seven continuous days the pilot will turn itself off When the main burner is lit again the cycle repeats The pilot will remain lit for seven days even after the main burn...

Page 35: ...LCD remote control display Replace batteries Battery Back up Red LED indicator will enter a 1 blink sequence IFC Module will emit a double beep when it receives an ON OFF command from the hand held r...

Page 36: ...n this manual Inspect the operation of the flame safety system pilot and gas valve Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Completely i...

Page 37: ...adjustments and orifice sizing IMPORTANT For high altitude installations above 4500 ft 1372 meters consult local gas distributor or the authority having jurisdiction for proper de rating methods WARNI...

Page 38: ...24 DVRS25NB N 2 38 CONVERSION KIT INSTRUCTIONS CONT VALVE CONVERSION...

Page 39: ...ures Test fire the fireplace to confirm correct operation Reinstall door assembly and surround Run through a complete firing cycle to confirm correct operation KIT NUMBERS 24 CKELP for LP gas and 24 C...

Page 40: ...305 2080 Fuse 3 15A 250V pack of 5 EA 301 0068 43 Orifice Main Burner Orifice Drill to 43 DMS for Natural Gas EA 301 0068 54 Orifice Main Burner Orifice Drill to 54 for LP Gas EA 308 0123 Pilot Assem...

Page 41: ...e is on and will continued as your fireplace completes its heating function You will likely hear these same sounds more on start up and shut down This is normal for steel fireplaces Q When my applianc...

Page 42: ...id if work is carried out by an unqualified person s Only original Brigantia parts may be used Please consult your Brigantia dealer or representative if in doubt about a replacement part s OBTAINING W...

Page 43: ...Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this warranty card mm dd yyyy POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LINE T...

Page 44: ...ARCHGARD FIREPLACES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Reviews: