24-DVRS25NB(N)-2
9
39 1/2”
1003 mm
11”
280 mm
26 1/2”
10”
254 mm
Framing Dimensions
The following section describes in detail
the requirements for framing for the
model 24
-
DVRS25NB(N)
-
2.
Note: Framing should be constructed
as required by local building codes
Construct the opening
to dimensions shown:
26 1/2”
wide x 39
1/2”
high X 5
1/2”
deep
The bottom of the
frame must be min
4”
up from combustible
floor
Installation Instructions
When installing on an exterior wall you must
include the exterior wall insulation and termi-
nation kit. Place insulation board with the foil
facing in to the room as shown in figure 3
Frame hole out opening and cut out hole for
the termination and thimble as shown in fig-
ure 1 and 2.
Figure 2
Figure 1
Figure 3
20”
508 mm
4”
102 mm
Minimum Distance to a
Combustible Floor