www.BrickElectric.com
http://192.168.1.105/ getpara[97]=1;
Socket command text:
getpara[97]=1;
To change device name to "my_device":
Web access URL:
http://192.168.1.105/ setpara[97]=my_device
Socket command text:
setpara[97]=my_device;
Read device type
you can read device type by communication, for the purpose of better identification the
device.
To read device type:
Web access URL:
http://192.168.1.105/ getpara[99]=1;
Socket command text:
getpara[99]=1;
Read device firmware version
you can read device firmware version by communication, for the purpose of better
identification the device, or diagnosis.
To read device firmware version:
Web access URL:
http://192.168.1.105/ getpara[98]=1;
Socket command text:
getpara[98]=1;
4.10 Read Inputs
BEM107 has one input channel, which can detect external contact condition. It is not
allowed to apply any external voltage to those input channels. You can read the input
parameters to check if the external contact is closed or opened.
Read input condition
You can read input channel 1 by:
Web access URL:
http://192.168.1.105/ getpara[189]=1;
Socket command text:
getpara[189]=1;