Page 2: ...TRICTION Despite the exerted efforts to make this Manual more exact some discre pancies may occur The information in this Manual is given on as is terms The author and the publisher do not bear any liability to a person or an or ganization for loss or damage which has arisen from the information con tained in this Manual CONTENTS ENG 1 SAFETY AND CAUTION MEASURES 2 PACKAGE CONTENTS 3 APPLICATION 4 ...

Page 3: ... It is prohibited to open and repair the device on your own It is prohibited to open and repair any protected equipment if it is con nected to the device socket It is prohibited to use the device with mechanical damages of its case It is prohibited to use the device in high humidity conditions Avoid ingress of water into the device Does not require special conditions for realization Dispose of in ...

Page 4: ...indication Protective shutters in the output socket Protective grounding contacts fusible safety device 15А 5 TECHNICAL DESCRIPTION RN 15 voltage relay presents a device with an electronic circuit with mic roprocessor control assembled in the case with a wall plug and socket RN 15 voltage relay has fixed settings and does not need programming RN 15 voltage relay provides the power supply disconnect...

Page 5: ...ntrance voltage range cIndicator high entrance voltage range d ON button of a force connecting of loading e Wall plug to connect the voltage relay to 230 V 50 Hz power supply network socket f Protective shutters g Grounding contacts f g b c d a e 5 User s Manual ENG Fig 1 RN 15 ...

Page 6: ...des normal operation protection mode turn on delay mode The voltage relay is in normal operation when the active voltage of the power supply network is within 199 252 V limit and the turn on delay time is over In this mode the protected equipment connected to the relay is de energized the indicator b lights continuously If the voltage exceeds the set thresholds the relay enters the protection mode...

Page 7: ...ximum permissible load kW Protection actuation time The maximum suppressed energy of high voltage pulses J The maximum absorbed impulse noise current A Operation threshold to decrease power supply voltage V Operation threshold to increase power supply voltage V Output socket Dimensions mm Weight kg Coulor Value 100 280 50 15 0 max 3 3 0 3 sec 125 4500 199 2 252 2 1 СЕЕ 7 4 72 86 39 max 78 0 115 wh...

Page 8: ...D 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandinavia Ltd 15 Kotolah dentie Kotka Finland 48310 Made in China Registered Trademark of Oy SVEN Scandinavia Ltd Finland Voltage Relay RN 15 ...