18
Troubleshooting
Motor head safety cut-off
The mixer is equipped with a motor head
safety cut-off. If the mixer head is lifted up at
any time while the mixer motor is switched on,
the safety cut-off will automatically switch the
motor off and set the mixer into standby mode.
To restart the motor within 5 minutes, lower
the mixer head into the horizontal (closed)
position, and turn the dial away then back to
the required speed setting. This will resume
mixing and the timer will resume counting.
To restart the motor after 5 minutes or more,
lower the mixer head and turn the dial to OFF
then back to the required speed.
The timer will start from 0.
To turn the mixer off (instead of restarting),
turn the dial to OFF, and unplug from the wall.
Electronic protection cut-off
(current overload)
The mixer is equipped with an electronic
protection cut-off and will automatically
stop operating if the motor is stalled
or overloaded. This is normally due to
excessive quantity in the mixing bowl.
Should the mixer go into this mode, the LED
indicator band will flash and the error message
“E1” will flash on the LCD screen and the
buzzer will beep 3 times.
If this error occurs, turn the speed control dial
to the OFF position, and unplug the cord.
Remove some of the ingredients in the mixing
bowl and then restart the mixer.
Thermo protection cut-off
(temperature overload)
The mixer is equipped with a self-resetting
safety device which safeguards against
overheating the motor with excessive
loads. If overheating occurs, the mixer will
automatically activate the overheating
protection device and the motor will switch
itself off. If this error occurs, turn the speed
control dial to the ‘OFF’ position, and unplug
the cord. Wait at least 15 minutes before
restarting the mixer.
Should the mixer go into this mode, the LED
indicator band will flash and the error message
“E2” will flash on the LCD screen and the
buzzer will “beep” 3 times.
If this error occurs, turn the speed control dial
to the ‘OFF’ position, and unplug the cord.
Wait at least 15 minutes before restarting
the mixer.