background image

DE

  

AT

    

CH

  

BE

Bei Fragen zum Produkt und eventuellen 

Reklamationen nehmen Sie bitte zunächst mit 

dem Service-Center Kontakt auf, vorzugsweise 

per E-Mail.  

E-Mail:

 

[email protected]

Telefon*:  +49 28 72 80 74 210
BRESSER GmbH

Kundenservice

Gutenbergstr. 2

46414 Rhede

Deutschland

* Lokale Rufnummer in Deutschland (Die Höhe der Gebühren je 

Telefonat ist abhängig vom Tarif Ihres Telefonanbieters); Anrufe aus 

dem Ausland sind mit höheren Kosten verbunden.

GB

  

IE

Please contact the service centre first for any 

questions regarding the product or claims, 

preferably by e-mail.   

e-mail: [email protected]

Telephone*: +44 1342 837 098
BRESSER UK Ltd

Suite G3, Eden House

Enterprise Way

Edenbridge, Kent TN8 6HF

United Kingdom

* Number charged at local rates in the UK (the amount you will be 

charged per phone call will depend on the tariff of your phone 

provider); calls from abroad will involve higher costs.

FR

  

BE

Si vous avez des questions concernant ce 

produit ou en cas de réclamations, veuillez 

prendre contact avec notre centre de services 

(de préférence via e-mail).  

e-mail: [email protected]

Téléphone*: 00 800 6343 7000
BRESSER France SARL

Pôle d'Activités de Nicopolis

260, rue des Romarins

83170 Brignoles

France 

* Prix d'un appel local depuis la France ou Belgique

Service

NL

  

BE

Als u met betrekking tot het product vragen 

of eventuele klachten heeft kunt u contact 

opnemen met het service centrum (bij voorkeur 

per e-mail).  

e-mail: [email protected]

Teléfono*:  +31 528 23 24 76
Folux B.V.

Smirnoffstraat 8

7903 AX  Hoogeveen 

Nederlands

*  Het telefoonnummer wordt in het Nederland tegen lokaal tarief 

in rekening gebracht. Het bedrag dat u per gesprek in rekening 

gebracht zal worden, is afhankelijk van het tarief van uw telefoon 

provider; gesprekken vanuit het buitenland zullen hogere kosten 

met zich meebrengen.

ES

  

PT

Si desea formular alguna pregunta sobre el 

producto o alguna eventual reclamación, le 

rogamos que se ponga en contacto con el 

centro de servicio técnico (de preferencia por 

e-mail).  

e-mail: servicio.iberia@bresser-iberia.

es

Teléfono*:  +34 91 67972 69
BRESSER Iberia SLU

c/Valdemorillo,1 Nave B

P.I. Ventorro del cano

28925  Alcorcón Madrid

España

* Número local de España (el importe de cada llamada telefónica 

dependen de las tarifas de los distribuidores); Las llamadas des del 

extranjero están ligadas a costes suplementarios.

Summary of Contents for Weather Center XXL JC + sensor 5in1

Page 1: ...Weather Station Weather Center XXL JC sensor 5in1 EN Instruction manual...

Page 2: ...ant le code QR ou le lien correspondant NL Bezoek onze internetpagina via de volgende QR code of weblink voor meer informatie over dit product of de beschikbare vertalingen van deze gebruiksaanwijzing...

Page 3: ...14 Automatic time setting 11 15 Manual time setting 11 16 Time zone setting 11 17 Receiving measurements automatically 12 18 Receiving measurements automatically 12 19 Rainfall 12 20 Manual measuremen...

Page 4: ...4 35 EC Declaration of Conformity 19 36 Cleaning and maintenance 19 37 Disposal 19 38 Warranty 20...

Page 5: ...in this documentation are gen erally protected by trade trademark and or patent law in Germany the European Union and or other countries 2 Validity note This documentation is valid for the products wi...

Page 6: ...button switch between highest low est or current value display 5 HISTORY button retrieve measurements for the past 24 hours 6 UP button increase value 7 DOWN button decrease value 8 TIME button manua...

Page 7: ...meter 7 Pipe clamp 8 Mounting shoe 9 Mounting bar 10 Battery compartment cover 11 RESET button 12 LED function indicator 13 Mounting screws with nuts 7 Scope of delivery Base station A power adapter B...

Page 8: ...ls like temperature wind chill dew point and heat index 14 Beaufort scale for wind force classification 15 Outdoor humidity 16 Sensor signal strength indicator 17 Outdoor temperature 18 Weather foreca...

Page 9: ...ote that the effective range is vastly affected by building materials and position of the main and re mote units Due to external influences various RC devices and other sources of interference the max...

Page 10: ...nt to the North Assembly on a vertical or horizontal wooden element 1 Slide one end of the assembly bar into the aperture below the sensor head 2 Slide one screw through the bore hole and put on the n...

Page 11: ...signal icon turns on If the clock fails to receive the time signal go ahead with the following steps 1 Press RCC button on the base station until radio signal symbol flashes 2 If the device is still...

Page 12: ...rainfall Monthly rainfall Select display mode Press the RAIN key repeatedly until the desired time period is shown on the display RATE Current precipitation of the last hour DAILY Total precipitation...

Page 13: ...ut a need to reset the clock and re establish pairing Simply press and hold the HIS TORY button for 10 seconds This will clear out any data recorded before 23 Pointing the sensor to the south The sens...

Page 14: ...n hemisphere it moves from left to right Below are the 2 tables which illustrate how the moon will appear on the main unit A 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 Illustration 4 A Northern hemisphere B So...

Page 15: ...next setting value 5 Press the UP or DOWN key to change the REL value according to the researched value 6 Finally press the CLOCK SET button to save the settings and exit the setting mode NOTICE ABS...

Page 16: ...88 km h 88 km h Select wind speed unit 1 Press the WIND button for approx 3 seconds to enter the setting mode 2 Press the UP or DOWN button to change the unit between mph miles per hour m s miles per...

Page 17: ...CHILL is displayed Note The wind chill factor is based on the common effects of temperature and wind speed The displayed wind chill is calculated solely from temperature and wind speed and is measured...

Page 18: ...Outdoor min temperature Outdoor max humidity Outdoor min humidity Indoor max temperature Indoor min temperature Indoor max humidity Indoor min humidity Outdoor max wind chill Outdoor min wind chill O...

Page 19: ...hermo hygro sensor 5 Unscrew the 2 screws at the bottom of the radiation shield 6 Gently pull out the shield 7 Remove carefully any dirt or insects inside the sensor casing Note The radiation shield c...

Page 20: ...hargeable batteries are marked with a symbol of a crossed out dustbin and the chemical symbol of the pollutant Cd stands for Cadmium Hg stands for mercury and Pb stands for lead 38 Warranty The regula...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...ail sav bresser fr T l phone 00 800 6343 7000 BRESSER France SARL P le d Activit s de Nicopolis 260 rue des Romarins 83170 Brignoles France Prix d un appel local depuis la France ou Belgique Service N...

Reviews: