Breckwell
7
FLOOR PROTECTOR
The stove must be placed on solid concrete, solid masonry, or when installed on a combustible
fl
oor, on a
fl
oor protector. The
fl
oor
protector is required to provide heat, live ember, and ash protection and must be of a non-combustible, continuous solid surface to
protect against in
fi
ltration of live embers and ash. If a
fl
oor pad is used, it should be listed to UL 1618 (type 1 ember protection) or
equal. For UL Listed
fl
oor protectors, refer to manufacturers instructions for installation directions.
Dimension
Inch
mm
J
Stove Width
33
838
K
Stove Depth
31
787
L
⃰⃰
Front
16
406
M
Back
0
0
N
⃰
⃰
Left
8
203
P
⃰
⃰
Right
8
203
⃰
Canadian installations require 18” (457mm)
⃰
⃰
Canadian installations require 8” (203mm)
CLEARANCES TO COMBUSTIBLES
INSERT STOVE CLEARANCES
SIDE W
A
LL
MANTEL
TOP TRIM
SIDE TRIM
FLOOR PROTECTOR
A
D
B
C
A:
Side wall: 18” (457mm) to side of appliance
B:
Top Trim: 18” (457mm) above top of appliance
C:
Side trim: 18” (457mm) to side of appliance
D:
Mantle: 28” (711mm) above top of appliance