background image

Breckwell 

13

CHIMNEY CONNECTOR (STOVE PIPE)

Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we recommend you 

contact your dealer in order to insure there will be no problem with the draft.

The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021” or 0.53 mm. It is strictly forbidden 

to use galvanized steel.

Your stove pipe should be assembled in such a way that the male section (crimped end) of the pipe faces down. Attach each of the 

sections to one another with three equidistant metal screws. Seal the joints with furnace cement.

The pipe must be short and straight. All sections installed horizontally must slope at least 1/4 inch per foot, with the upper end of 

the section toward the chimney. Any installation with a horizontal run of stove pipe must conform to NFPA 211. You may contact 
NFPA (National Fire Protection Association) and request the latest edition of the NFPA Standard 211.

To insure a good draft, the total length of the stove pipe should never exceed 8’ to 10’ (2.4m to 3.04 m). (Except for cases of 

vertical installation, cathedral-roof style where the smoke exhaust system can be much longer and connected without problem to 
the chimney at the ceiling of the room).

There should never be more than two 90 degrees elbows in the smoke exhaust system.
Installation of a “barometric draft stabilizer” (

fi

 replace register) on a smoke exhaust system is prohibited.

Furthermore, installation of a draft damper is not recommended. With a controlled combustion wood stoves the draft is regulated 

upon intake of the combustion air in the stove and not at the exhaust.

To

Appliance

Summary of Contents for SW940

Page 1: ...nstallation in the USA and Canada SAFETY TESTED TO UL 1482 2011 ULC S627 2000 and ULC S628 US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE WASHINGTON STATE APPROVED SAVE THESE INSTRUCT...

Page 2: ...DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCHAS GASOLINE NAPHTHAOR MOTOR OIL DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM ALWAYS...

Page 3: ...d DO NOT remove the baffle board TOOLS AND MATERIALS NEEDED FOR INSTALLATION You must choose one of the three offered kits A Pedestal Kit SA940P B Leg Kit SA940L C Fireplace Insert SA940i Refer to the...

Page 4: ...k the kit and ensure all components are present Four 4 Cast Iron Legs 40566 Eight 8 1 4 20 UNC Bolts 83339 and Eight 8 Flat Washers 83045A 1 Position the unit for assembly 2 Using the Eight 8 1 4 20 b...

Page 5: ...rk behind facade panels 4 Realign the first side panel with the mark made previously 5 Using the predrilled holes in the facade panel as a guide mark and drill holes for the self tapping screws used t...

Page 6: ...lacement of hot air accelerated upwards and its replacement with cooler air If necessary the hot air distribution from the stove may be facilitated by the installation of a blower Route power cord awa...

Page 7: ...e 1 ember protection or equal For UL Listed floor protectors refer to manufacturers instructions for installation directions Dimension Inch mm J Stove Width 33 838 K Stove Depth 31 787 L Front 16 406...

Page 8: ...n Non Combustible Floor Make a 2 x 7 51mm x 177mm cutout through both the floor protector and home s flooring aligned with the knockout in the pedistal base Dryer Venting Kit Installation If your choi...

Page 9: ...draft effect your stove s performance is directly dependent on an adequate draft from your chimney Do not connect this unit to a chimney flue serving another appliance The following recommendations ma...

Page 10: ...does not weaken any structural components of the existing fireplace or chimney nor reduces protection of combustible materials required by national building codes Consult with your local building or f...

Page 11: ...ted by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the st...

Page 12: ...connector and a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiber...

Page 13: ...ot with the upper end of the section toward the chimney Any installation with a horizontal run of stove pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and requ...

Page 14: ...the same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearanc...

Page 15: ...eld Blackened windows Incomplete log combustion Smaller pieces of wood will dry faster All logs exceeding 6 in diameter should be split The wood should not be stored directly on the ground Air should...

Page 16: ...ng the paper and kindling wood inside the combustion chamber When you have achieved a good bed of hot embers we recommend the following burn procedures OPERATION Controlled combustion is the most effi...

Page 17: ...oke exhaust pipe approximately 18 above the stove This thermometer will indicate the temperature of your gas exhaust fumes within the smoke exhaust system The ideal temperature for these gases is some...

Page 18: ...lass gasket to make sure you keep it sealed Never wash the glass with a product that may scratch Use a specialized product available in the stores where wood stoves are sold The glass should be washed...

Page 19: ...Ash Pan 1 30 26401 Front Ash Pan 1 31 BS 099 1 2 In Rope Gasket 1 Key Part No Description Qty 32 89284 Rtv Black Silicone 1 33 69872 Ash Plug 1 34 88173 Cement Furnace 10 1 Oz 3M Fireblock 1 35 88082...

Page 20: ...20 Breckwell REPAIR PARTS DIAGRAMS 38 41 49 51 50 43 45 44 39 42 40 47 46 37 48 14 2 36 16 29 19 5 10 3 4 11 9 12 13 18 18 17 6 8 19 5 7 1 30 33 34 35 20 23 22 15 26 27 25 27 28 31 32...

Page 21: ...Pedestal Back 1 58 26415 Access Panel 1 59 26416 Pedestal 2 SA940I Key Part Description Qty 60 26411 Surround Top 1 61 26412 Surround Left 1 62 26413 Surround Right 1 63 26414 Clamp Top Trim 1 64 8922...

Page 22: ...tached to the stove When ordering repair parts always give the following information as shown in this list HOW TO ORDER REPAIR PARTS 1 The part number ___________________________________________ 3 The...

Page 23: ...___________ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read...

Page 24: ...24 Breckwell CUT HERE CUT HERE Fold Here Fold Here Breckwell P O Box 750 Bridgeport AL 35740 Fold Here PLACE STAMP HERE...

Reviews: