SB
I-240
Service Manual
49
LINE
CAL.P0
Line calibration point0
Do zero point calibration. This point
can't be omitted.
CAL.P1
Line calibration point1
First weight point calibration. This
point can't be omitted and standard
weight must be over 10%FS.
END.Y
YES
End calibration?
YES=go to CAL.END to end
NO=go to do next point calibration
NO
CAL.P2
Line calibration point2
Second weight point calibration.
Standard weight must be over
10%FS and be larger than it in
CAL.P1. This point can be omitted.
END.Y
YES
End calibration?
YES=go to CAL.END to end
NO=go to do next point calibration
NO
CAL.P3
Line calibration point3:
Third weight point calibration.
Standard weight must be over
10%FS and be larger than it in
CAL.P2, this point can be omitted.
geo
code
00-70
Select geograhical position
Code 00-70
gravt
9.76183-
9.99999
Input gravity of user location
input
Input or view calibration
parameter values
Only used to copy calibration
parameters from one scale to a new
scale.
cal.end
Calibration end and restart
CAL
Submenu1
Submenu2
Option Parameter Description
Comment
Summary of Contents for SBI-240
Page 1: ...SBI 240 Weighing Indicator Service Manual AWT35 501 Issue AA ...
Page 5: ...SBI 240 Service Manual 5 ...
Page 7: ......
Page 9: ...ti E ...
Page 10: ......
Page 34: ...TARE PRESET SBI 240 Service Manual ...
Page 57: ...SBI 240 Service Manual 55 Table 5 1 Location Code For Elevation and Latitude ...
Page 76: ...74 SBI 240 Service Manual ...
Page 77: ......