SB
I-240
Service Manual
23
7.
Press the
TARE/PRESET
key to confirm.
8.
Once an acceptable piece weight has been entered, the scale will return to
counting mode.
3.8 Check Counts (count compare) in Counting Mode
The Check Counts function allows the user to enter a pre-set range. The display will
indicate whether the weighed value is within that range or indicate if it is too high or too
low.
1.
Press and hold the
UNIT/DATA
key for 4 seconds to access the comparative
data range.
2.
HIGH will be shown and
000000
will be displayed.
The HI annunciator on the display will be lit.
3.
Use the
keys to input the upper limit of the range (weight, piece
quantity, or percentage depending on initial mode).
4.
Press the
TARE/PRESET
key to confirm and move to the next step.
5.
Low will be shown and
000000
will be displayed. The LO annunciator on the
display will be lit.
6.
Use the
keys to enter the lower limit of the range.
7.
Press the
TARE/PRESET
key to confirm.
NOTE: If the input piece weight is less than 0.5d (where d = the scale's readability,
see specifications), the indicator will display PWt.Er and will automatically return to
counting mode.
NOTE: The piece weight that has been entered will be saved, even after powering off.
The indicator can only save one piece weight.
Entering a new piece weight will automatically replace the old one.
NOTE: If the upper limit is 0, or if it is less than or equal to the lower limit, check
weighing mode will automatically be exited.
Summary of Contents for SBI-240
Page 1: ...SBI 240 Weighing Indicator Service Manual AWT35 501 Issue AA ...
Page 5: ...SBI 240 Service Manual 5 ...
Page 7: ......
Page 9: ...ti E ...
Page 10: ......
Page 34: ...TARE PRESET SBI 240 Service Manual ...
Page 57: ...SBI 240 Service Manual 55 Table 5 1 Location Code For Elevation and Latitude ...
Page 76: ...74 SBI 240 Service Manual ...
Page 77: ......