MS140-300 

Operation Manual 

 
 

Contents subject to change without notice 

 
 
 
 
 
 

Version 2.1 

2012-01-10 

 
 
 
 
 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MS140/300

Page 1: ...MS140 300 Operation Manual Contents subject to change without notice Version 2 1 2012 01 10...

Page 2: ...aux appareils num riques de la Classe A prescrites dans le R glement sur le brouillage radio lectrique edict par le minist re des Communications du Canada Warnings Electrical installation For your pro...

Page 3: ...c device These devices emit RF and can cause unstable scale readings If your scale ever performs poorly try moving the scale to a different room or location Avoid using in condition of heavy vibration...

Page 4: ...tivity 0 3mV V 3mV V must be fit to 0 2uV display grad 2 Input Resistor 80 3 Output Resistor 10 K LOADCELL WIRING PIN 1 RED EXCITATION PIN2 BLACK EXCITATION PIN3 GREEN SIGNAL PIN4 WHITE SIGNAL 3 KEY F...

Page 5: ...ormal weighing mode and hold down time longer than 3s 1 Same meaning with that in 3 1 2 Same meaning with that in 3 1 3 Same meaning with that in 3 1 4 Power off the scale UNIT TARE ZERO HOLD PRINT UN...

Page 6: ...oint dot in calibration unit P9 and capacity s unit in calibration P10 If the setting of FS is more than 199999 regardless of decimal point and weight unit the FS capacity will be shown by first four...

Page 7: ...d data will blink If the indicator gets reasonable data it will calculate and store all parameters in EEPROM And then it will auto reset and display all segments of LCD full capacity like power on aga...

Page 8: ...Detailed setup 5 1 P1 xy Auto off time xy 00 15 xy 00 means no auto off function xy 01 15 means the scale turns off to save power after 01 15 minutes when no variety of weight on scale and no key ope...

Page 9: ...put compatible 8 data to the NCI SP1 format 5 5 P5 x Baud rate of RS232 communication x 0 1200bps x 1 2400bps x 2 4800bps x 3 9600bps x 4 19200bps 5 6 P6 x RS232 communication data format x 0 8N1 8 di...

Page 10: ...lb Not available 0 0002 lb 0 0001 kg 0 0002 lb Not available 0 002 lb 0 001 kg 0 002 lb Not available 0 02 lb 0 01 kg 0 02 lb 0 5 oz 15 0 2 lb 0 1 kg 0 2 lb 5 oz 2 lb 1 kg 2 lb Not available 20 lb 10...

Page 11: ...power off zero point as power on zero point and power off tare weight as current tare weight 5 16 P16 x Zero tracking range x 0 0d means no tracking x 1 0 25d x 2 0 5d x 3 1d x 4 1 5d x 5 2d x 6 3d x...

Page 12: ...f the zero point is error it will return nine _ characters b The character will be for negative weight or a space character for positive 19 weight Minus sign follows after the first digit c Useless le...

Page 13: ...ip of capacity and the setting of P7 P8 and P9 Table6 Capacity unit is kg or lb Resolution set by P7 Division set by P8 and P9 P8 0 0 0001 0 001 0 01 0 1 1 10 500 0 0500 0 500 5 00 50 0 500 5000 600 0...

Page 14: ...160000 1600000 100000 20 0000 200 000 2000 00 20000 0 200000 2000000 23 Table8 Capacity unit is kg or lb Resolution set by P7 Division set by P8 and P9 P8 2 0 0005 0 005 0 05 0 5 5 50 500 0 2500 2 50...

Page 15: ...as following drawings 1 Placed vertically 2 Placed horizontally 25 Key Definition summary KEY MODE DEFINITION HOLD PRINT Normal weighing mode Enter or exit HOLD mode output the data as per P4 P5 P6 s...

Page 16: ...x 0 1 2 3 4 3 Baud rate for RS232 0 1200bps 1 2400bps 2 4800bps 3 9600bps 4 19200bps 27 P6 x 0 1 2 0 RS232 format 0 8N1 1 7O1 2 7E1 P7 xy 00 31 13 Resolution select 500 600 750 800 1000 1200 1500 200...

Page 17: ...play 0 P16 x 0 1 2 3 4 5 6 7 8 8 Zero tracking range 0 0d no tracking 1 0 25d 2 0 5d 3 1d 4 1 5d 5 2d 6 3d 7 4d 8 5d P17 x 0 1 2 3 2 Data filter intensity 0 very weak 1 weak 2 middle 3 strong P18 x 0...

Page 18: ...845 246 6717 Fax 44 0 845 246 6718 Email sales brecknellscales co uk Web site www brecknellscales co uk USA Brecknell 1000 Armstrong Drive Fairmont MN 56031 Toll Free 800 637 0529 Tel 507 238 8702 Fa...