10
GP100 and GP250 User Instructions
8.
Press the
[TARE]
key to exit the setting and return the scale to
0.0
weight.
2.3 Unit Switching Configuration
The default setting for switching is ON. In this menu you can change the scale to weigh
in kilograms (kg) only, pounds (lb) only, or units switching on.
To change units:
1.
With the scale turned on, remove all weight from the scale.
2.
Press and hold the
[TARE]
key for 3 seconds. The display will read
TARE
,
SET
,
Unit
To turn OFF units switching and weigh in lbs only:
1.
Press the
[TARE]
key enter into configuration menu. The display will read
kg
2.
Press
[TARE]
key. The display will read
ON
3.
Press the
[UNITS]
key once to scroll to
OFF
4.
Press
[TARE]
key. The display will read
0.1
5.
Press the
[TARE]
key. The display will read
kg
6.
Press the
[UNITS]
key 5 times. The display will read
END
7.
Press the
[TARE]
key to exit the setting and return the scale to
0.0
weight.
2.4 Scale Calibration
Periodically your scale may require calibration to ensure proper weighing. Calibration
may be required if the scale has been improperly used by mishandling or by dropping
the scale. You will need an accurate 50 or 200 pound weight to calibrate the scale. If
calibration is performed with a weight other than 50 or 200 pounds, it will cause your
scale to weigh inaccurately.
IMPORTANT: Do not enter into Calibration Mode without an accurate weight.
To calibrate the scale:
1.
Make sure the scale is turned off.
2.
Remove all weight from the scale.
3.
Press and hold the
[ZERO/ON-OFF]
key and press the
[UNITS]
key three
times. The display will read
CAL
.
3a.
Press
[TARE]
to display current calibration units;
KG
or
LB
.
3b.
Press
[UNITS]
to select an alternate calibration unit;
KG
or
LB
.
3c.
Press
[TARE]
to advance to scale capacity;
100
or
250
.
3d.
Press
[TARE]
to return to "
CAL
".
Summary of Contents for GP100-USB